Search results
Results from the WOW.Com Content Network
A 20-volt level was added in a revision named "class B" of the specification. [12] [13] The voltage range of the successor Pump Express Plus 2.0 is between 5 volts and 20 volts, with 0.5 volts steps. The Quick Charge 3.0 protocol supports finer-grain voltage levels with 0.2 volts steps and has a lower minimum voltage of approximately 3.3 volt.
Electronic components have a wide range of failure modes. These can be classified in various ways, such as by time or cause. Failures can be caused by excess temperature, excess current or voltage, ionizing radiation, mechanical shock, stress or impact, and many other causes. In semiconductor devices, problems in the device package may cause ...
The charger may have temperature or voltage sensing circuits and a microprocessor controller to safely adjust the charging current and voltage, determine the state of charge, and cut off at the end of charge. Chargers may elevate the output voltage proportionally with current to compensate for impedance in the wires. [3]
Electrical equipment may be designed with a floating ground for one of several reasons. One is safety. For example, a low-voltage DC power supply, such as a mobile phone charger, is connected to the mains through a transformer of one type or another, and there is no direct electrical connection between the current return path on the low-voltage side and physical ground (earth).
Free carrier concentration is the concentration of free carriers in a doped semiconductor. It is similar to the carrier concentration in a metal and for the purposes of calculating currents or drift velocities can be used in the same way. Free carriers are electrons that have been introduced into the conduction band (valence band) by doping ...
The ground potential at different outlets may differ by as much as 10 to 20 volts [4] due to voltage drops from these currents. The diagram shows leakage current from an appliance such as an electric motor A flowing through the building's ground system G to the neutral wire at the utility ground bonding point at the service panel .
In electronic design and power transmission, various techniques are employed to compensate for the effect of voltage drop on long circuits or where voltage levels must be accurately maintained. The simplest way to reduce voltage drop is to increase the diameter of the conductor between the source and the load, which lowers the overall resistance.
Trickle charging is the process of charging a fully charged battery at a rate equal to its self-discharge rate, enabling the battery to remain at its fully charged level. This state occurs almost exclusively when the battery is not loaded, as trickle charging will not keep a battery charged if current is being drawn by a load.