Search results
Results from the WOW.Com Content Network
Radiant heating and cooling is a category of HVAC technologies that exchange heat by both convection and radiation with the environments they are designed to heat or cool. There are many subcategories of radiant heating and cooling, including: "radiant ceiling panels", [ 1 ] "embedded surface systems", [ 1 ] "thermally active building systems ...
A chiller boiler system is a hydronic system. It uses water instead of air to heat and cool a structure. A properly designed hydronic system is usually more efficient than a standard forced air system. [1] Chiller boiler systems use radiant heating and cooling or fan coil systems to condition a home or business. This allows for multiple zones ...
The two-pipe reverse return configuration which is sometimes called 'the three-pipe system' is different from the two-pipe system in the way that water returns to the boiler. In a two-pipe system, once the water has left the first radiator, it returns to the boiler to be reheated, and so with the second and third etc.
The steam piping (with steam flowing through it) is directed through the flue gas path in the boiler furnace. This area typically is between 1,300–1,600 °C (2,372–2,912 °F). Some superheaters are radiant type (absorb heat by thermal radiation), others are convection type (absorb heat via a fluid i.e. gas) and some are a combination of the ...
Hydronic radiant floor heating systems use a boiler or district heating to heat water and a pump to circulate the hot water in plastic pipes installed in a concrete slab. The pipes, embedded in the floor, carry heated water that conducts warmth to the surface of the floor, where it broadcasts heat energy to the room above.
The older fire-tube boiler design, in which the water surrounds the heat source and gases from combustion pass through tubes within the water space, is typically a much weaker structure and is rarely used for pressures above 2.4 MPa (350 psi). A significant advantage of the watertube boiler is that there is less chance of a catastrophic failure ...
Piping and instrumentation diagram of pump with storage tank. Symbols according to EN ISO 10628 and EN 62424. A more complex example of a P&ID. A piping and instrumentation diagram (P&ID) is defined as follows: A diagram which shows the interconnection of process equipment and the instrumentation used to control the process.
Diagram of natural draft gas furnace, early 20th century. The first category of furnaces is natural draft, atmospheric burner furnaces. These furnaces consisted of cast-iron or riveted-steel heat exchangers built within an outer shell of brick, masonry, or steel. The heat exchangers were vented through brick or masonry chimneys.