Search results

  1. Results from the WOW.Com Content Network
  2. Blood pressure measurement - Wikipedia

    en.wikipedia.org/wiki/Blood_pressure_measurement

    A minimum systolic value can be roughly estimated by palpation, most often used in emergency situations, but should be used with caution. [10] It has been estimated that, using 50% percentiles, carotid, femoral and radial pulses are present in patients with a systolic blood pressure > 70 mmHg, carotid and femoral pulses alone in patients with systolic blood pressure of > 50 mmHg, and only a ...

  3. Blood pressure - Wikipedia

    en.wikipedia.org/wiki/Blood_pressure

    35094-2. Blood pressure (BP) is the pressure of circulating blood against the walls of blood vessels. Most of this pressure results from the heart pumping blood through the circulatory system. When used without qualification, the term "blood pressure" refers to the pressure in a brachial artery, where it is most commonly measured.

  4. Auscultatory gap - Wikipedia

    en.wikipedia.org/wiki/Auscultatory_gap

    It is therefore recommended to palpate and auscultate when manually recording a patient's blood pressure. [3] Typically, the blood pressure obtained via palpation is around 10 mmHg lower than the pressure obtained via auscultation. In general, the examiner can avoid being confused by an auscultatory gap by always inflating a blood pressure cuff ...

  5. Korotkoff sounds - Wikipedia

    en.wikipedia.org/wiki/Korotkoff_sounds

    The five Korotkoff sounds. There are five Korotkoff sounds: [7] Phase I: The first appearance of faint, repetitive, clear tapping sounds which gradually increase in intensity for at least two consecutive beats is the systolic blood pressure. Phase II: A brief period may follow during which the sounds soften and acquire a swishing quality.

  6. Continuous noninvasive arterial pressure - Wikipedia

    en.wikipedia.org/wiki/Continuous_noninvasive...

    Benefit of CNAP technology. Continuous noninvasive arterial blood pressure measurement (CNAP) combines the advantages of the following two clinical “gold standards”: it measures blood pressure (BP) continuously in real-time like the invasive arterial catheter system (IBP) and it is non-invasive like the standard upper arm sphygmomanometer ...

  7. Mean arterial pressure - Wikipedia

    en.wikipedia.org/wiki/Mean_arterial_pressure

    MeSH. D062186. In medicine, the mean arterial pressure (MAP) is an average calculated blood pressure in an individual during a single cardiac cycle. [1] Although methods of estimating MAP vary, a common calculation is to take one-third of the pulse pressure (the difference between the systolic and diastolic pressures), and add that amount to ...