Search results
Results from the WOW.Com Content Network
Resolution and resolving power, when defined in this way, are consistent with IUPAC recommendations for microscopy, optical spectroscopy. [16] [17] and ion microscopy (SIMS) [18] but not gas chromatography. [13] This definition also appears in some mass spectrometry texts. [19] [20] [21]
Chromatographic peak resolution is given by = + where t R is the retention time and w b is the peak width at baseline. The bigger the time-difference and/or the smaller the bandwidths, the better the resolution of the compounds. Here compound 1 elutes before compound 2.
In engineering and physics, g c is a unit conversion factor used to convert mass to force or vice versa. [1] It is defined as = In unit systems where force is a derived unit, like in SI units, g c is equal to 1.
3) Changing α is the most effective way of increasing resolution. This can be done by choosing a stationary phase that has a greater difference between k 1 ' and k 2 '. It can also be done in L.C. by using pH to invoke secondary equilibria (if applicable). The fundamental resolution equation is derived as follows:
One of the most widely used methods for headspace analysis is described by the United States Environmental Protection Agency (USEPA). Originally developed by the R.S. Kerr USEPA Laboratory in Ada, Oklahoma as a "high quality, defendable, and documented way to measure" methane, ethane, and ethene, [7] [8] RSKSOP-175 is a standard operating procedure (SOP) and an unofficial method employed by ...
Image scaling can be interpreted as a form of image resampling or image reconstruction from the view of the Nyquist sampling theorem.According to the theorem, downsampling to a smaller image from a higher-resolution original can only be carried out after applying a suitable 2D anti-aliasing filter to prevent aliasing artifacts.
Static (previously anamorphic) refers to when both the vertical and horizontal components of the FOV are fixed, typically to values comfortable on a widescreen picture, and when the resolution changes the picture is either letterboxed or pillarboxed to maintain the field of view and aspect ratio. Modern games using static scaling typically have ...
From the variables in the figure above, the resolution, plate number, and plate height of the column plate model can be calculated using the equations: Resolution (R s): R s = 2(t RB – t RA)/(w B + w A), where: t RB = retention time of solute B t RA = retention time of solute A w B = Gaussian curve width of solute B w A = Gaussian curve width ...