Single-pole circuit breakers feed 120 V circuits from one of the 120 V buses within the panel, or two-pole circuit breakers feed 240-volt circuits from both buses. 120 V circuits are the most common, and used to power NEMA 1 and NEMA 5 outlets, and most residential and light commercial direct-wired lighting circuits.
This standard established 120 volt nominal system and two ranges for service voltage and utilization voltage variations. [19] Today, virtually all American homes and businesses have access to 120 and 240 V at 60 Hz. Both voltages are available on the three wires (two "hot" legs of opposite phase and one "neutral" leg).
So if A–B, B–C and C–A are all 240 volts, then A–N and C–N will both be 120 volts, but B–N will be 208 volts. Other types of three-phase supplies are wye connections, ungrounded delta connections, or corner-grounded delta [2] (ghost leg configuration) connections. These connections do not supply split single-phase power, and do not ...
Consequently, this allows homeowners to wire up both 240 V and 120 V circuits as they wish (as regulated by local building codes). Most sockets are connected to 120 V for the use of small appliances and electronic devices, while larger appliances such as dryers, electric ovens, ranges and EV chargers use dedicated 240 V sockets.
Most of the Americas use 60 Hz AC, the 120/240 volt split-phase system domestically and three phase for larger installations. North American transformers usually power homes at 240 volts, similar to Europe's 230 volts. It is the split-phase that allows use of 120 volts in the home. Japan's utility frequencies are 50 Hz and 60 Hz.
For example a 120/240 V rating can disqualify a circuit breaker for use with a delta system load that would otherwise work with a wye system load.
Vacuum circuit-breakers can be qualified as a generator circuit-breakers (GCB) according to IEC/IEEE 62271-37-013. Compared to circuit-breakers using other quenching media (such as SF6, air-blast or minimum oil), vacuum circuit-breakers have the advantages of:
Generator circuit breaker rated for 17.5 kV and 63 kA. Generator circuit breakers (GCB) are connected between a generator and the step-up voltage transformer. They are generally used at the outlet of high-power generators (30 MVA to 1800 MVA) in order to protect them in a reliable, fast and economic manner.