Search results
Results from the WOW.Com Content Network
Nominal Pipe Size (NPS) is a North American set of standard sizes for pipes used for high or low pressures and temperatures. [1] " Nominal" refers to pipe in non-specific terms and identifies the diameter of the hole with a non-dimensional number (for example – 2-inch nominal steel pipe" consists of many varieties of steel pipe with the only criterion being a 2.375-inch (60.3 mm) outside ...
A Fixture Unit is not a flow rate unit but a design factor. A fixture unit is equal to 1 cubic foot (0.028 m 3) of water drained in a 1 + 1 ⁄ 4 inches (32 mm) diameter pipe over one minute. [2] One cubic foot of water is roughly 7.48 US gallons (28.3 L; 6.23 imp gal). A Fixture Unit is used in plumbing design for both water supply and waste ...
National Pipe Taper Fuel (NPTF, also called Dryseal American National Standard Taper Pipe Thread, defined by ASME B1.20.3) is designed to provide a more leak-free seal without the use of PTFE tape (often referred to by the popular brand name "Teflon") or another sealant compound. NPTF threads have the same basic shape but with crest and root ...
Executive Order 12770, signed by President George H. W. Bush on July 25, 1991, citing the Metric Conversion Act, directed departments and agencies within the executive branch of the United States Government to "take all appropriate measures within their authority" to use the metric system "as the preferred system of weights and measures for ...
These standard pipe threads are formally referred to by the following sequence of blocks: the words, Pipe thread, the document number of the standard (e.g., ISO 7 or EN 10226) the symbol for the pipe thread type: G, external and internal parallel (ISO 228) R, external taper (ISO 7) Rp, internal parallel (ISO 7/1) Rc, internal taper (ISO 7)
For example, NPS 14 has an OD of 14 inches or 355.60 millimetres, and is equivalent to DN 350. Since the outside diameter is fixed for a given pipe size, the inside diameter will vary depending on the wall thickness of the pipe. For example, 2" Schedule 80 pipe has thicker walls and therefore a smaller inside diameter than 2" Schedule 40 pipe.
This page was last edited on 22 August 2016, at 10:48 (UTC).; Text is available under the Creative Commons Attribution-ShareAlike 4.0 License; additional terms may ...
While pipe sizes in Australia are inch-based, they are classified by outside rather than inside diameter (e.g., a nominal 3 ⁄ 4 inch copper pipe in Australia has measured diameters of 0.750 inches outside and 0.638 inches inside, whereas a nominal 3 ⁄ 4 inch copper pipe in the U.S. and Canada has measured diameters of 0.875 inch outside and ...