  2. Autotransformer - Wikipedia

    en.wikipedia.org/wiki/Autotransformer

    In electrical engineering, an autotransformer is an electrical transformer with only one winding. The "auto" (Greek for "self") prefix refers to the single coil acting alone. In an autotransformer, portions of the same winding act as both the primary winding and secondary winding sides of the transformer. In contrast, an ordinary transformer ...

  3. Korndörfer autotransformer starter - Wikipedia

    en.wikipedia.org/wiki/Korndörfer_Autotransformer...

    This basic principle explains the source of the destructive transient voltage in the Korndörfer motor starter apparatus. A further transient problem is that with a single coil construction and a star switch, the autotransformer acts as a step-up transformer during the <5 microsecond period at contact separation of the Star point switch.

  4. Voltage converter - Wikipedia

    en.wikipedia.org/wiki/Voltage_converter

    A transformer or autotransformer can be used; (auto)transformers are inherently reversible, so the same transformer can be used to step the voltage up, or step it down by the same ratio. Lighter and smaller devices can be made using electronic circuitry; reducing the voltage electronically is simpler and cheaper than increasing it.

  5. Zigzag transformer - Wikipedia

    en.wikipedia.org/wiki/Zigzag_transformer

    A conventional six-winding, grounding transformer or zigzag bank, [1] with the same winding and core quantity as a conventional three-phase transformer, can also be used in zigzag winding connection. In all cases the first coil on each zigzag winding core is connected contrariwise to the second coil on the next core.

  6. Transformer types - Wikipedia

    en.wikipedia.org/wiki/Transformer_types

    For example, an auto transformer that adapts a 1000 VA load rated at 120 volts to a 240 volt supply has an equivalent rating of at least: 1,000 VA (240 V – 120 V) / 240 V = 500 VA. However, the actual rating (shown on the tally plate) must be at least 1000 VA.

  7. Center tap - Wikipedia

    en.wikipedia.org/wiki/Center_tap

    For example, a 24 VCT transformer will measure 24 VAC across the outer two taps (winding as a whole), and 12 VAC from each outer tap to the center-tap (half winding). These two 12 VAC supplies are 180 degrees out of phase with each other, measured with respect to the tap, thus making it easy to derive positive and negative 12 volt DC power ...

  8. Tap changer - Wikipedia

    en.wikipedia.org/wiki/Tap_changer

    However, a transformer may include a tap changer on each winding if there are advantages to do so. For example, in power distribution networks, a large step-down transformer may have an off-load tap changer on the primary winding and an on load automatic tap changer on the secondary winding or windings. The high voltage tap is set to match long ...

  9. Push–pull converter - Wikipedia

    en.wikipedia.org/wiki/Push–pull_converter

    In practice, it is necessary to allow a small interval between powering the transformer one way and powering it the other: the “switches” are usually pairs of transistors (or similar devices), and were the two transistors in the pair to switch simultaneously there would be a risk of shorting out the power supply.