The general standard IEC 60601-1 – Medical electrical equipment – Part 1: General requirements for basic safety and essential performance – gives general requirements of the series of standards. 60601 is a widely accepted benchmark for medical electrical equipment and compliance with IEC60601-1 has become a requirement for the commercialisation of electrical medical equipment in many ...
An X-ray generator generally contains an X-ray tube to produce the X-rays. Possibly, radioisotopes can also be used to generate X-rays. [1]An X-ray tube is a simple vacuum tube that contains a cathode, which directs a stream of electrons into a vacuum, and an anode, which collects the electrons and is made of tungsten to evacuate the heat generated by the collision.
Backscatter X-ray is an advanced X-ray imaging technology. Traditional X-ray machines detect hard and soft materials by the variation in x-ray intensity transmitted through the target. In contrast, backscatter X-ray detects the radiation that reflects from the target. It has potential applications where less-destructive examination is required ...
The IRR99 make legal requirements including prior authorisation of the use of particle accelerators and x-ray machines, the appointment of radiation protection supervisors (RPS) and advisers (RPA), control and restriction of exposure to ionising radiation (including dose limits), and a requirement for local rules.
With the advancement of image processing software the number applications for automated x-ray inspection is huge and constantly growing. The first applications started off in industries where the safety aspect of components demanded a careful inspection of each part produced (e.g. welding seams for metal parts in nuclear power stations) because the technology was expectedly very expensive in ...
It was also more economical for a hospital to have a dual machine that could apply treatments of electrons and X-rays, instead of two machines. The Therac-25 was designed as a machine controlled by a computer, with some safety mechanisms switched from hardware to software as a result.
X-ray generators produce X-rays by applying a high voltage between the cathode and the anode of an X-ray tube and in heating the tube filament to start the electron emission. The electrons are then accelerated in the resulting electric potential and collide with the anode, which is usually made of Tungsten .
The first scientific evaluations of these machines in 1948 immediately sparked concern for radiation protection and electrical safety reasons, and found them ineffective at shoe fitting. [6] Large variations in dose were possible depending on the machine design, displacement of the shielding materials, and the duration and frequency of use.