Search results
Results from the WOW.Com Content Network
The heating value depends on the source of gas that is used and the process that is used to liquefy the gas. The range of heating value can span ±10 to 15 percent. A typical value of the higher heating value of LNG is approximately 50 MJ/kg or 21,500 BTU/lb. [2] A typical value of the lower heating value of LNG is 45 MJ/kg or 19,350 BTU/lb.
It is the rate of heat transfer needed to freeze 1 short ton (907 kg) of water into ice in 24 hours. In the United States and Canada, the R-value that describes the performance of thermal insulation is typically quoted in square foot degree Fahrenheit hours per British thermal unit (ft 2 ⋅°F⋅h/Btu).
As another example, a regulation might limit the concentration of particulate matter to 0.1 grain per standard cubic foot (i.e., scf) of dry exhaust gas corrected to 12 volume percent CO 2. Environmental agencies in the USA often denote a standard cubic foot of dry gas as "dscf" or as "scfd".
Dry ice is typically produced in three standard forms: large blocks, small (1 ⁄ 2 or 5 ⁄ 8 in [13 or 16 mm] diameter) cylindrical pellets and tiny (1 ⁄ 8 inch [3.2 mm] diameter) cylindrical, high surface to volume pellets that float on oil or water and do not stick to skin because of their high radii of curvature.
Million standard cubic feet per day is a unit of measurement for gases that is predominantly used in the United States. It is frequently abbreviated MMSCFD. It is frequently abbreviated MMSCFD. MMSCFD is commonly used as a measure of natural gas , liquefied petroleum gas , compressed natural gas and other gases that are extracted, processed or ...
As an example, a measured NO x concentration of 45 ppmv in a dry gas having 5 volume % O 2 is: 45 × ( 20.9 - 3 ) ÷ ( 20.9 - 5 ) = 50.7 ppmv of NO x. when corrected to a dry gas having a specified reference O 2 content of 3 volume %. Note: The measured gas concentration C m must first be corrected to a dry basis before using the above equation.
Yet other definitions are in use for industrial gas, [5] where, in the US, a standard cubic foot for industrial gas use is defined at 70 °F (21.1 °C) and 14.696 psia (101.325 kPa), while in Canada, a standard cubic meter for industrial gas use is defined at 15 °C (59 °F) and 101.325 kPa (14.696 psia).
For gases, departure from 3 R per mole of atoms is generally due to two factors: (1) failure of the higher quantum-energy-spaced vibration modes in gas molecules to be excited at room temperature, and (2) loss of potential energy degree of freedom for small gas molecules, simply because most of their atoms are not bonded maximally in space to ...