Semko 17 were 3/4-pin 3-phase connectors, with (4-pin) or without (3-pin) a neutral connector. Earth were provided via the shield. The connectors were available in different sizes, 16 A with rounded corners; 25 A and 63 A were rectangular. These connectors were used mainly in industrial and agricultural installations.
A three-wire three-phase circuit is usually more economical than an equivalent two-wire single-phase circuit at the same line-to-ground voltage because it uses less conductor material to transmit a given amount of electrical power. [3] Three-phase power is mainly used directly to power large induction motors, other electric motors and other ...
The pins are arranged at 120° angles around a common midpoint, with the active and neutral centred 7.92 mm (5 ⁄ 16 in) from the midpoint, and the earth pin centred 10.31 mm (3 ⁄ 8 in) away. [15] A standard socket-outlet provides a nominal RMS voltage of 230 volts [2] at a maximum of 10 amps and always includes an earth connection ...
"Switched socket-outlets and connectors with or without interlock" applies to self-contained products that combine within a single enclosure, a socket-outlet or connector according to IEC 60309-1 or IEC 60309-2 and a switching device, with a rated operating voltage not exceeding 1000 VDC or VAC and 500 Hz, and a rated current not exceeding 800 A.
As an example, the 5-15R is the common 125 V two-pole, three-wire receptacle rated for 15 A. The L5-15R, while sharing the same electrical rating, is a locking design that is not physically compatible with the straight-blade 5-15 design. The 5-30R has the same two-pole, three-wire configuration and 125 V rating, but is rated for 30 A.
The IET Wiring Regulations permit an unlimited number of 13A socket outlets (at any point unfused single or double, or any number fused) to be installed on a ring circuit, provided that the floor area served does not exceed 100 m 2. In practice, most small and medium houses have one ring circuit per storey, with larger premises having more.
For power circuits, the color-coding uses the same colors as residential construction, and adds the additional wires used for three-phase systems. Black, Red and Blue are used for hot wires and White is used as the neutral wire in a 120/208 V circuit. Brown, Orange and Yellow are used as hot wires and gray is used as the neutral wire in a 277/ ...
Long wiring runs are limited by the permitted voltage drop limit in the conductors. Because the supply voltage is doubled, a balanced load can tolerate double the voltage drop, allowing quarter-sized conductors to be used; this uses 3/8 the copper of an equivalent single-phase system. In practice, some intermediate value is chosen.