enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Electrical outlet tester - Wikipedia

    en.wikipedia.org/wiki/Electrical_outlet_tester

    A receptacle tester being used to check for some types of improper wiring of an outlet. For this particular tester, proper wiring is indicated by the two yellow lights. The outlet tester checks that each contact in the outlet appears to be connected to the correct wire in the building's electrical wiring. It can identify several common wiring ...

  3. Residual-current device - Wikipedia

    en.wikipedia.org/wiki/Residual-current_device

    A residual-current device (RCD), residual-current circuit breaker (RCCB) or ground fault circuit interrupter (GFCI) [a] is an electrical safety device, more specifically a form of Earth-leakage circuit breaker, that interrupts an electrical circuit when the current passing through line and neutral conductors of a circuit is not equal (the term residual relating to the imbalance), therefore ...

  4. Portable appliance testing - Wikipedia

    en.wikipedia.org/wiki/Portable_appliance_testing

    A leakage current test is an alternative to the insulation resistance test. A deficiency of the insulation resistance test is that the DC voltage will not activate electromagnetic switches or internal relays etc. that are common in many modern power tools, computers, and TVs, etc. and therefore it can only test the appliance up to those components.

  5. Arc-fault circuit interrupter - Wikipedia

    en.wikipedia.org/wiki/Arc-fault_circuit_interrupter

    In 2002, the NEC removed the word "receptacle", leaving "outlets", with the effect that lights and other wired-in devices such as ceiling fans within bedrooms were added to the requirement. The 2005 code made it clearer that all outlets must be protected despite discussion in the code-making panel about excluding bedroom smoke detectors from ...

  6. Smith chart - Wikipedia

    en.wikipedia.org/wiki/Smith_chart

    Using the Smith chart, the normalised impedance may be obtained with appreciable accuracy by plotting the point representing the reflection coefficient treating the Smith chart as a polar diagram and then reading its value directly using the characteristic Smith chart scaling. This technique is a graphical alternative to substituting the values ...

  7. Tektronix - Wikipedia

    en.wikipedia.org/wiki/Tektronix

    Starting with the 530 and 540 series oscilloscopes, the operator could switch in different horizontal sweep or vertical input plug-ins. This allowed the oscilloscope to be an adaptable test instrument. Later Tektronix added plug-ins to have the scope operate as a spectrum analyzer, waveform sampler, cable tester and transistor curve tracer.

  8. Bootleg ground - Wikipedia

    en.wikipedia.org/wiki/Bootleg_ground

    A receptacle with a bootleg ground. In building wiring installed with separate neutral and protective ground bonding conductors (a TN-S network), a bootleg ground (or a false ground) is a connection between the neutral side of a receptacle or light fixture and the ground lug or enclosure of the wiring device.

  9. ANSI device numbers - Wikipedia

    en.wikipedia.org/wiki/ANSI_device_numbers

    A suffix letter or number may be used with the device number; for example, suffix N is used if the device is connected to a Neutral wire (example: 59N in a relay is used for protection against Neutral Displacement); and suffixes X, Y, Z are used for auxiliary devices.