enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Useful conversions and formulas for air dispersion modeling

    en.wikipedia.org/wiki/Useful_conversions_and...

    If a gaseous emission sample is analyzed and found to contain water vapor and a pollutant concentration of say 40 ppmv, then 40 ppmv should be designated as the "wet basis" pollutant concentration. The following equation can be used to correct the measured "wet basis" concentration to a "dry basis" concentration: [3]

  3. Air pollutant concentrations - Wikipedia

    en.wikipedia.org/wiki/Air_pollutant_concentrations

    The conversion equations depend on the temperature at which the conversion is wanted (usually about 20 to 25 °C). At an ambient sea level atmospheric pressure of 1 atm (101.325 kPa or 1.01325 bar ), the general equation is:

  4. Conversion of units - Wikipedia

    en.wikipedia.org/wiki/Conversion_of_units

    Conversion of units is the conversion of ... .325 kPa absolute pressure. ... the fractions in the above equation, the NO x concentration of 10 ppm v converts to ...

  5. Partial pressure - Wikipedia

    en.wikipedia.org/wiki/Partial_pressure

    The atmospheric pressure is roughly equal to the sum of partial pressures of constituent gases – oxygen, nitrogen, argon, water vapor, carbon dioxide, etc.. In a mixture of gases, each constituent gas has a partial pressure which is the notional pressure of that constituent gas as if it alone occupied the entire volume of the original mixture at the same temperature. [1]

  6. Standard cubic centimetres per minute - Wikipedia

    en.wikipedia.org/wiki/Standard_cubic_centimetres...

    Standard cubic centimeters per minute (SCCM) is a unit used to quantify the flow rate of a fluid. 1 SCCM is identical to 1 cm³ STP /min. Another expression of it would be Nml/min.

  7. Dobson unit - Wikipedia

    en.wikipedia.org/wiki/Dobson_unit

    The Dobson unit (DU) is a unit of measurement of the amount of a trace gas in a vertical column through the Earth's atmosphere.It originated by, and continues to be primarily used in respect to, the study of atmospheric ozone, whose total column amount, usually termed "total ozone", and sometimes "column abundance", is dominated by the high concentrations of ozone in the stratospheric ozone layer.

  8. Pressure coefficient - Wikipedia

    en.wikipedia.org/wiki/Pressure_coefficient

    In fluid dynamics, the pressure coefficient is a dimensionless number which describes the relative pressures throughout a flow field. The pressure coefficient is used in aerodynamics and hydrodynamics. Every point in a fluid flow field has its own unique pressure coefficient, C p.

  9. Antoine equation - Wikipedia

    en.wikipedia.org/wiki/Antoine_equation

    The coefficients of Antoine's equation are normally given in mmHg—even today where the SI is recommended and pascals are preferred. The usage of the pre-SI units has only historic reasons and originates directly from Antoine's original publication. It is however easy to convert the parameters to different pressure and temperature units.