enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Template:Table of MRI sequences - Wikipedia

    en.wikipedia.org/.../Template:Table_of_MRI_sequences

    High signal for paramagnetic substances, such as MRI contrast agents [2] Standard foundation and comparison for other sequences T2 weighted: T2: Measuring spin–spin relaxation by using long TR and TE times Higher signal for more water content [1] Low signal for fat in standard Spine Echo (SE), [1] though not with Fast Spin Echo/Turbo Spin ...

  3. MRI pulse sequence - Wikipedia

    en.wikipedia.org/wiki/MRI_pulse_sequence

    An MRI pulse sequence in magnetic resonance imaging (MRI) is a particular setting of pulse sequences and pulsed field gradients, resulting in a particular image appearance. [ 1 ] A multiparametric MRI is a combination of two or more sequences, and/or including other specialized MRI configurations such as spectroscopy .

  4. Fast low angle shot magnetic resonance imaging - Wikipedia

    en.wikipedia.org/wiki/Fast_low_angle_shot...

    Fast low angle shot magnetic resonance imaging (FLASH MRI) is a particular sequence of magnetic resonance imaging. It is a gradient echo sequence which combines a low-flip angle radio-frequency excitation of the nuclear magnetic resonance signal (recorded as a spatially encoded gradient echo) with a short repetition time .

  5. Magnetic resonance imaging - Wikipedia

    en.wikipedia.org/wiki/Magnetic_resonance_imaging

    Magnetic resonance imaging (MRI) is a medical imaging technique used in radiology to generate pictures of the anatomy and the physiological processes inside the body. MRI scanners use strong magnetic fields, magnetic field gradients, and radio waves to form images of the organs in the body.

  6. Steady-state free precession imaging - Wikipedia

    en.wikipedia.org/wiki/Steady-state_free...

    Steady-state free precession (SSFP) imaging is a magnetic resonance imaging (MRI) sequence which uses steady states of magnetizations. In general, SSFP MRI sequences are based on a (low flip angle) gradient echo MRI sequence with a short repetition time which in its generic form has been described as the FLASH MRI technique. While spoiled ...

  7. List of neuroscience databases - Wikipedia

    en.wikipedia.org/wiki/List_of_neuroscience_databases

    MRI Healthy No [17] Cambridge Centre for Ageing and Neuroscience (Cam-CAN) MRI, fMRI, MEG data for ~700 population-derived healthy adults aged 18–88 Human Macroscopic Images, Descriptive, Numerical Healthy No [18] The Cancer Imaging Archive MRI, CT, and PET imaging of cancer patients with supporting clinical data (in many cases) Human Macroscopic

  8. Spin echo - Wikipedia

    en.wikipedia.org/wiki/Spin_echo

    Fast spin echo (RARE, FAISE or FSE [10] [11] [12]), also called turbo spin echo (TSE) is an MRI sequence that results in fast scan times. In this sequence, several 180 refocusing radio-frequency pulses are delivered during each echo time (TR) interval, and the phase-encoding gradient is briefly switched on between echoes. [ 13 ]

  9. Real-time MRI - Wikipedia

    en.wikipedia.org/wiki/Real-time_MRI

    In general, real time MRI relies on gradient echo sequences, efficient k-space sampling, and fast reconstruction methods to speed up the image acquisition process. [11] Gradient echo sequences present shorter echo times since only one RF pulse is required for each sequence. [ 12 ]