enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Celloscope automated cell counter - Wikipedia

    en.wikipedia.org/wiki/Celloscope_automated_cell...

    As cells are counted in an absolute volume of the suspension, the number of cells in mm 3 of whole blood can be calculated using the dilution factor. The described automated Celloscope cell count method enabled an improved accuracy compared with manual examination by microscopy, while decreasing manual work for the operator.

  3. Colony-forming unit - Wikipedia

    en.wikipedia.org/wiki/Colony-forming_unit

    Counting with colony-forming units requires culturing the microbes and counts only viable cells, in contrast with microscopic examination which counts all cells, living or dead. The visual appearance of a colony in a cell culture requires significant growth, and when counting colonies , it is uncertain if the colony arose from a single cell or ...

  4. Cell counting - Wikipedia

    en.wikipedia.org/wiki/Cell_counting

    Cell counting is any of various methods for the counting or similar quantification of cells in the life sciences, including medical diagnosis and treatment. It is an important subset of cytometry , with applications in research and clinical practice.

  5. Hemocytometer - Wikipedia

    en.wikipedia.org/wiki/Hemocytometer

    Phytoplankton cell counting; Cell processing for downstream analysis: accurate cell numbers are needed in many tests (PCR, flow cytometry), while some others require high cell viability. Measurement of cell size: in a micrograph, the real cell size can be inferred by scaling it to the width of a hemocytometer square, which is known. [7]

  6. Miles and Misra method - Wikipedia

    en.wikipedia.org/wiki/Miles_and_Misra_method

    In each sector, 1 x 20 μl of the appropriate dilution is dropped onto the surface of the agar and the drop allowed to spread naturally. In the original description of the method a drop from a height of 2.5 cm spread over an area of 1.5-2.0 cm. It is important to avoid touching the surface of the agar with the pipette.

  7. Virtual colony count - Wikipedia

    en.wikipedia.org/wiki/Virtual_colony_count

    For the experimental portion of the assay, cells are diluted in 10 mM sodium phosphate pH 7.4 such that the final cell concentration in 10 microliters is 5x10 6 CFUv/mL. 10 μl of this cell suspension are pipetted beneath the 90 μl of antimicrobial peptides in solution, resulting in a cell suspension at the standard inoculum of 5x10 5 CFUv/mL ...

  8. Serial dilution - Wikipedia

    en.wikipedia.org/wiki/Serial_dilution

    A serial dilution is the step-wise dilution of a substance in solution, either by using a constant dilution factor, or by using a variable factor between dilutions. If the dilution factor at each step is constant, this results in a geometric progression of the concentration in a logarithmic fashion. A ten-fold serial dilution could be 1 M, 0.1 ...

  9. Virus quantification - Wikipedia

    en.wikipedia.org/wiki/Virus_quantification

    Plaque formation can take 3–14 days, depending on the virus being analyzed. Plaques are generally counted manually, and the plaque count, in combination with the dilution factor of the infection solution (the sample initially applied to the cells), is used to calculate the number of plaque forming units per sample unit volume (PFU/mL). The ...