Search results
Results from the WOW.Com Content Network
In anteroposterior (AP) views, the positions of the x-ray source and detector are reversed: the x-ray beam enters through the anterior aspect and exits through the posterior aspect of the chest. AP chest x-rays are harder to read than PA x-rays and are therefore generally reserved for situations where it is difficult for the patient to get an ...
However, a lumbar spine X-ray has a similar dose as a head CT. [150] Articles in the media often exaggerate the relative dose of CT by comparing the lowest-dose X-ray techniques (chest X-ray) with the highest-dose CT techniques. In general, a routine abdominal CT has a radiation dose similar to three years of average background radiation. [151]
The flight-time equivalent dose concept is the creation of Ulf Stahmer, a Canadian professional engineer working in the field of radioactive materials transport. It was first presented in the poster session [1] at the 18th International Symposium of the Packaging and Transport of Radioactive Materials (PATRAM) held in Kobe, Hyogo, Japan where the poster received an Aoki Award for distinguished ...
Computed tomography or CT scan (previously known as CAT scan, the "A" standing for "axial") uses ionizing radiation (x-ray radiation) in conjunction with a computer to create images of both soft and hard tissues. These images look as though the patient was sliced like bread (thus, "tomography" – "tomo" means "slice").
The radiation exposure from consuming a banana is approximately 1% of the average daily exposure to radiation, which is 100 banana equivalent doses (BED). The maximum permitted radiation leakage for a nuclear power plant is equivalent to 2,500 BED (250 μSv) per year, while a chest CT scan delivers 70,000 BED (7 mSv).
The average radiation dose from an abdominal X-ray is 0.7 millisieverts (0.0007 Sv), that from an abdominal CT scan is 8 mSv, that from a pelvic CT scan is 6 mGy, and that from a selective CT scan of the abdomen and the pelvis is 14 mGy. [7]
Human internal radiation due to radon, varies with radon levels [8] 2 2 × 10 ^ 0: Acute-Head CT [7] 3 3 × 10 ^ 0: Annual: 0.34: USA average dose from all natural sources [6] 3.66 3.66 × 10 ^ 0: Annual: 0.42: USA average from all sources, including medical diagnostic radiation doses [citation needed] 4 4 × 10 ^ 0: Duration of the pregnancy: 0.6
Low-dose high-resolution (1.25 mm) chest CT. HRCT is performed using a conventional CT scanner. However, imaging parameters are chosen so as to maximize spatial resolution: [1] a narrow slice width is used (usually 1–2 mm), a high spatial resolution image reconstruction algorithm is used, field of view is minimized, so as to minimize the size of each pixel, and other scan factors (e.g. focal ...