In North American practice, for residential and light commercial buildings fed with a single-phase split 120/240 service, an overhead cable from a transformer on a power pole is run to the service entrance point. The cable is a three conductor twisted "triplex" cable with a bare neutral and two insulated conductors, with no overall cable jacket ...
Cable glands and self-sealing grommets are usually designed for entering single or just a few cables. By utilising a gland plate, many cables with different diameters can be routed. Depending on the type, very high cable densities or ingress protection classes up to IP66/IP68 (according to IEC 60529) can be achieved.
In electric power distribution, a service drop is an overhead electrical line running from a utility pole, to a customer's building or other premises. It is the point where electric utilities provide power to their customers. [1] The customer connection to an underground distribution system is usually called a "service lateral".
Above-ground lines cost around $10 per 1-foot (0.30 m) and underground lines cost in the range of $20 to $40 per 1-foot (0.30 m). [10] In highly urbanized areas, the cost of underground transmission can be 10–14 times as expensive as overhead. [11] However, these calculations may neglect the cost of power interruptions.
The cable linking the telephone exchange to local customers is a thick cable lashed to a thin supporting cable, containing hundreds of twisted pair subscriber lines. Each twisted pair line provides a single telephone circuit or local loop to a customer. There may also be FOCs interconnecting telephone exchanges.
If the MI cable jacket has been damaged, the magnesium oxide will wick moisture into the cable, and it will lose its insulating properties, causing shorts to the copper cladding and thence to earth. It is often necessary to remove 0.5 to 2 metres (1.6 to 6.6 ft) of the MI cable and splice in a new section to accomplish the repair.
Discover the latest breaking news in the U.S. and around the world — politics, weather, entertainment, lifestyle, finance, sports and much more.
This does not include the uninsulated ground wire. For instance, if the cable lists "12-2 AWG", it means there are two insulated 12-gauge wires (a black and a white wire), plus a ground wire. If the label says "12-3", this cable has four conductors—three 12-gauge insulated wires and a bare copper ground wire. [5]