enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Internally grooved copper tube - Wikipedia

    en.wikipedia.org/wiki/Internally_grooved_copper_tube

    To use smaller tubes instead of conventional-sized tubes in air conditioners, heat exchangers must be redesigned including the fin and tube circuits. [12] Design optimization requires the use of computational fluid dynamics to analyze airflow around the tubes and fins, as well as computer simulations of refrigerant flow and temperatures inside the tubes.

  3. Heat exchanger - Wikipedia

    en.wikipedia.org/wiki/Heat_exchanger

    Some DX coils are "microchannel" type. [5] On the air side of HVAC coils a significant difference exists between those used for heating, and those for cooling. Due to psychrometrics, air that is cooled often has moisture condensing out of it, except with extremely dry air flows. Heating some air increases that airflow's capacity to hold water.

  4. Direct exchange geothermal heat pump - Wikipedia

    en.wikipedia.org/wiki/Direct_exchange_geothermal...

    A direct exchange (DX) geothermal heat pump is a type of ground source heat pump in which refrigerant circulates through copper tubing placed in the ground unlike other ground source heat pumps where refrigerant is restricted to the heat pump itself with a secondary loop in the ground filled with a mixture of water and anti-freeze.

  5. Fan coil unit - Wikipedia

    en.wikipedia.org/wiki/Fan_coil_unit

    Fan coil units linked to ducted split air conditioning units use refrigerant in the cooling coil instead of chilled coolant and linked to a large condenser unit instead of a chiller. They might also be linked to liquid-cooled condenser units which use an intermediate coolant to cool the condenser using cooling towers.

  6. Chiller - Wikipedia

    en.wikipedia.org/wiki/Chiller

    A liquid (glycol based) chiller with an air cooled condenser on the rooftop of a medium size commercial building. In air conditioning systems, chilled coolant, usually chilled water mixed with ethylene glycol, from a chiller in an air conditioning or cooling plant is typically distributed to heat exchangers, or coils, in air handlers or other types of terminal devices which cool the air in ...

  7. Crankcase heater - Wikipedia

    en.wikipedia.org/wiki/Crankcase_heater

    A crankcase heater is an electrical component in a compressor in an air-conditioning system, heat pump system, or chiller system. The crankcase heater is normally on all the time, even when the unit is not running, though temperature sensors and set points may turn it off when not needed.

  8. Thermal expansion valve - Wikipedia

    en.wikipedia.org/wiki/Thermal_expansion_valve

    A thermal expansion valve is a key element to a heat pump; this is the cycle that makes air conditioning, or air cooling, possible. A basic refrigeration cycle consists of four major elements: a compressor, a condenser, a metering device and an evaporator. As a refrigerant passes through a circuit containing these four elements, air ...

  9. Economizer - Wikipedia

    en.wikipedia.org/wiki/Economizer

    For example, for a walk-in freezer that is kept at −20 °F (−29 °C), the main refrigeration components would include: an evaporator coil (a dense arrangement of pipes containing refrigerant and thin metal fins used to remove heat from inside the freezer), fans to blow air over the coil and around the box, an air-cooled condensing unit ...