enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. R-value (insulation) - Wikipedia

    en.wikipedia.org/wiki/R-value_(insulation)

    The R-value is the building industry term [3] for thermal resistance "per unit area." [4] It is sometimes denoted RSI-value if the SI units are used. [5] An R-value can be given for a material (e.g. for polyethylene foam), or for an assembly of materials (e.g. a wall or a window). In the case of materials, it is often expressed in terms of R ...

  3. List of insulation materials - Wikipedia

    en.wikipedia.org/wiki/List_of_insulation_materials

    This is a list of insulation materials used around the world. Typical R-values are given for various materials and structures as approximations based on the average of available figures and are sorted by lowest value. R-value at 1 m gives R-values normalised to a 1 metre (3 ft 3 in) thickness and sorts by median value of the range.

  4. List of refrigerants - Wikipedia

    en.wikipedia.org/wiki/List_of_refrigerants

    According to ASHRAE standard 34, the R-number of a chemical refrigerant is assigned systematically according to its molecular structure and has between two and four digits. If there are carbon -carbon multiple bonds , there are four digits in all: the number of these bonds is the first digit and the number of carbon atoms minus one (C-1) is next.

  5. Building insulation - Wikipedia

    en.wikipedia.org/wiki/Building_insulation

    All thermal insulation requirements in ASHRAE 90.1 are divided by the climate zone, it means that the amount of insulation needed for a building is determined by which climate zone the building locates. The thermal insulation requirements are shown as R-value and continuous insulation R-value as the second index. [13]

  6. United States building energy codes - Wikipedia

    en.wikipedia.org/wiki/United_States_building...

    Provisions in the commercial sector of the model codes affect building design and construction factors such as: thermal envelope, water heating, HVAC, and lighting systems. [7] [22] In the 2021 IECC model code, for example, there are provisions that reference ASHRAE 90.1 concerning insulation R-values for opaque parts of the building envelope. [22]

  7. Building insulation material - Wikipedia

    en.wikipedia.org/wiki/Building_insulation_material

    While open-cell foams typically have R-values of 3 to 4 per inch (RSI-0.53 to RSI-0.70 per inch), closed-cell foams can attain R-values of 5 to 8 per inch (RSI-0.88 to RSI-1.41 per inch). This is important if space is limited, because it allows a thinner layer of insulation to be used.

  8. Cooling load temperature difference calculation method

    en.wikipedia.org/wiki/Cooling_load_temperature...

    The CLTD/CLF/SCL (cooling load temperature difference/cooling load factor/solar cooling load factor) cooling load calculation method was first introduced in the 1979 ASHRAE Cooling and Heating Load Manual (GRP-158) [1] The CLTD/CLF/SCL Method is regarded as a reasonably accurate approximation of the total heat gains through a building envelope ...

  9. Insulated siding - Wikipedia

    en.wikipedia.org/wiki/Insulated_siding

    Producers report an average R-value of 2.0 - 5.5, significantly more than that of other siding products including fiber cement, brick and stucco. Homeowners also report insulated siding serves as a noise barrier to external sound. Insulated vinyl siding with added fan fold foam board insulation raises the R-value to 3.5 - 7.5.