Search results

  1. Results from the WOW.Com Content Network
  2. Calibration curve - Wikipedia

    en.wikipedia.org/wiki/Calibration_curve

    A calibration curve plot showing limit of detection (LOD), limit of quantification (LOQ), dynamic range, and limit of linearity (LOL).. In analytical chemistry, a calibration curve, also known as a standard curve, is a general method for determining the concentration of a substance in an unknown sample by comparing the unknown to a set of standard samples of known concentration. [1]

  3. Primary standard - Wikipedia

    en.wikipedia.org/wiki/Primary_standard

    A primary standard in metrology is a standard that is sufficiently accurate such that it is not calibrated by or subordinate to other standards. Primary standards are defined via other quantities like length, mass and time. Primary standards are used to calibrate other standards referred to as working standards. [1] [2] See Hierarchy of Standards.

  4. Bradford protein assay - Wikipedia

    en.wikipedia.org/wiki/Bradford_protein_assay

    In summary, in order to find a standard curve, one must use varying concentrations of BSA (Bovine Serum Albumin) [2] in order to create a standard curve with concentration plotted on the x-axis and absorbance plotted on the y-axis. Only a narrow concentration of BSA is used (2-10 ug/mL) in order to create an accurate standard curve. [23]

  5. Laboratory quality control - Wikipedia

    en.wikipedia.org/wiki/Laboratory_quality_control

    An example of a Levey–Jennings chart with upper and lower limits of one and two times the standard deviation. A Levey–Jennings chart is a graph that quality control data is plotted on to give a visual indication whether a laboratory test is working well. The distance from the mean is measured in standard deviations.

  6. Internal standard - Wikipedia

    en.wikipedia.org/wiki/Internal_standard

    The calibration curve that does not use the internal standard method ignores the uncertainty between measurements. The coefficient of determination (R 2) for this plot is 0.9985. In the calibration curve that uses the internal standard, the y-axis is the ratio of the nickel signal to the yttrium signal.

  7. Standard solution - Wikipedia

    en.wikipedia.org/wiki/Standard_solution

    A standard solution created from a secondary standard cannot have its concentration accurately known without stoichiometric analysis against a primary standard. An example of a secondary standard is sodium hydroxide, a hydroscopic compound that is highly reactive with its surroundings. The concentration of a standard solution made with sodium ...

  8. Tris - Wikipedia

    en.wikipedia.org/wiki/Tris

    Tris is also used as a primary standard to standardize acid solutions for chemical analysis. Tris is used to increase permeability of cell membranes. [ 13 ] It is a component of the Moderna COVID-19 vaccine [ 14 ] and the Pfizer-BioNTech COVID-19 vaccine for use in children 5 through 11 years of age.

  9. Reaction progress kinetic analysis - Wikipedia

    en.wikipedia.org/wiki/Reaction_progress_kinetic...

    The combination leads to a standard set of curves in which reaction progress is read from right to left along the x-axis and reaction rate is read from bottom to top along the y-axis. [2] While these plots often provide a visually compelling demonstration of basic kinetic trends, differential methods are generally superior for extracting ...