enow.com Web Search

  1. Ad

    related to: osha ceiling limits 1910.1000 to 100
  2. jjsafetyllc.com has been visited by 10K+ users in the past month

    • Contact Us

      Reach Us Via Phone Or Form

      Request More Information

    • About Us

      Top In Class Service

      Safety Audit Strategy Consulting

Search results

  1. Results from the WOW.Com Content Network
  2. Permissible exposure limit - Wikipedia

    en.wikipedia.org/wiki/Permissible_exposure_limit

    OSHA's PEL for noise exposure is 90 decibels (dBA) for an 8-hour TWA. Levels of 90-140 dBA are included in the noise dose. [4] PEL can also be expressed as 100 percent “dose” for noise exposure. When the noise exposure increases by 5 dB, the exposure time is cut in half. [5] According to OSHA, a 95dBA TWA would be a 200 percent dose. [6]

  3. Hydrogen peroxide - Wikipedia

    en.wikipedia.org/wiki/Hydrogen_peroxide

    The U.S. Occupational Safety and Health Administration (OSHA) has established a permissible exposure limit of 1.0 ppm calculated as an 8-hour time-weighted average (29 CFR 1910.1000, Table Z-1). [97] Hydrogen peroxide has been classified by the American Conference of Governmental Industrial Hygienists (ACGIH) as a "known animal carcinogen, with ...

  4. Title 29 of the Code of Federal Regulations - Wikipedia

    en.wikipedia.org/wiki/Title_29_of_the_Code_of...

    100-199: National Labor Relations Board: II: 200-299: Office of Labor-Management Standards, Department of Labor: III: 300-399: National Railroad Adjustment Board: IV: 400-499: Office of Labor-Management Standards, Department of Labor 3: V: 500-899: Wage and Hour Division, Department of Labor 4: IX: 900-999: Construction Industry Collective ...

  5. List of highly toxic gases - Wikipedia

    en.wikipedia.org/wiki/List_of_highly_toxic_gases

    Toxic: a chemical that has a median lethal concentration (LC 50) in air of more than 200 parts per million (ppm) but not more than 2,000 parts per million by volume of gas or vapor, or more than 2 milligrams per liter but not more than 20 milligrams per liter of mist, fume or dust, when administered by continuous inhalation for 1 hour (or less if death occurs within 1 hour) to albino rats ...

  6. Disinfectant - Wikipedia

    en.wikipedia.org/wiki/Disinfectant

    The vapor is hazardous to the respiratory system and eyes and consequently the OSHA permissible exposure limit is 1 ppm (29 CFR 1910.1000 Table Z-1) calculated as an eight-hour time weighted average and the NIOSH immediately dangerous to life and health limit is 75 ppm. [30]

  7. Sterilization (microbiology) - Wikipedia

    en.wikipedia.org/wiki/Sterilization_(microbiology)

    The National Institute for Occupational Safety and Health's (NIOSH) immediately dangerous to life and health limit (IDLH) for EO is 800 ppm. [33] The odor threshold is around 500 ppm, [34] so EO is imperceptible until concentrations are well above the OSHA PEL. Therefore, OSHA recommends that continuous gas monitoring systems be used to protect ...

  8. Hydrogen safety - Wikipedia

    en.wikipedia.org/wiki/Hydrogen_safety

    For comparison the deflagration limit of gasoline in air is 1.4–7.6%, and of acetylene in air, [15] 2.5–82%. Therefore, when equipment is open to air before or after a transfer of hydrogen, there are unique conditions to take into consideration that might have otherwise been safe with transferring other kinds of gases.

  9. Isocyanate - Wikipedia

    en.wikipedia.org/wiki/Isocyanate

    OSHA puts forth permissible exposure limit (PEL) 20 ppb for MDI and detailed technical guidance on exposure assessment. [ 52 ] The National Institutes of Health ( NIOSH ) is the agency responsible for providing the research and recommendations regarding workplace safety, while OSHA is more of an enforcement body.

  1. Ad

    related to: osha ceiling limits 1910.1000 to 100