  2. Heat detector - Wikipedia

    en.wikipedia.org/wiki/Heat_detector

    Rate-of-Rise (ROR) heat detectors operate on a rapid rise in element temperature of 6.7 to 8.3°C (12.1 to 14.9°F) increase per minute, irrespective of the starting temperature. This type of heat detector can operate at a lower temperature fire condition than would be possible if the threshold were fixed.

  3. Fire alarm control panel - Wikipedia

    en.wikipedia.org/wiki/Fire_alarm_control_panel

    A fire alarm control panel (FACP), fire alarm control unit (FACU), fire indicator panel (FIP), or simply fire alarm panel is the controlling component of a fire alarm system. The panel receives information from devices designed to detect and report fires, monitors their operational integrity, and provides for automatic control of equipment, and ...

  4. Fire-resistance rating - Wikipedia

    en.wikipedia.org/wiki/Fire-resistance_rating

    The length of time required for a penetrant or sample on average to exceed a specified average heat rise above ambient at any single location determines the duration for the FT Rating (Fire and Temperature). If a hose-stream test is passed afterwards, the rating can then be expressed as an FTH Rating (Fire, Temperature and Hose-stream). The ...

  5. EN 54 - Wikipedia

    en.wikipedia.org/wiki/EN_54

    The EN 54 series of standards covers the following topics and product groups related to fire detection and fire alarm systems: [6] [7] Introduction: the introduction to the series of standards contains a diagram of a fire alarm system as well as numerous definitions of terms that are used in the other parts of the series of standards.

  6. Fire damper - Wikipedia

    en.wikipedia.org/wiki/Fire_damper

    Fire/smoke dampers are similar to fire dampers in fire resistance rating, and also prevent the spread of smoke inside the ducts. When a rise in temperature occurs, the fire damper closes, usually activated by a thermal element which melts at temperatures higher than ambient but low enough to indicate the presence of a fire, allowing springs to ...

  7. NFPA 72 - Wikipedia

    en.wikipedia.org/wiki/NFPA_72

    The NFPA 72 (National Fire Alarm and Signaling Code) is a standard published by the National Fire Protection Association every 3 years for installation of fire alarm systems and emergency communication systems in the United States.

  8. Control and indicating equipment - Wikipedia

    en.wikipedia.org/wiki/Control_and_Indicating...

    The fire detection and fire alarm system subcommittee of ISO/TC 21, Equipment for Fire Protection and Fire Fighting, had oversight for development of five standards covering detectors, control and indicating equipment. ISO 7240-2:3003 specifies requirements, test methods and performance criteria for control and indicating equipment (c.i.e.) for ...

  9. Fire sprinkler - Wikipedia

    en.wikipedia.org/wiki/Fire_sprinkler

    A fire sprinkler mounted on a ceiling. A fire sprinkler or sprinkler head is the component of a fire sprinkler system that discharges water when the effects of a fire have been detected, such as when a predetermined temperature has been exceeded. Fire sprinklers are extensively used worldwide, with over 40 million sprinkler heads fitted each year.