Load balancing, load matching, or daily peak demand reserve refers to the use of various techniques by electrical power stations to store excess electrical power during low demand periods for release as demand rises. [1] The aim is for the power supply system to have a load factor of 1.
Daily load diagram; Blue shows real load usage and green shows ideal load. Load management, also known as demand-side management (DSM), is the process of balancing the supply of electricity on the network with the electrical load by adjusting or controlling the load rather than the power station output.
Load flow study is an important tool involving numerical analysis applied to a power system. The load flow study usually uses simplified notations like a single-line diagram and focuses on various forms of AC power rather than voltage and current. It analyzes the power systems in normal steady-state operation.
Load balancing or load distribution may refer to: Load balancing (computing), balancing a workload among multiple computer devices; Load balancing (electrical power), the storing of excess electrical power by power stations during low demand periods, for release as demand rises; Network load balancing, balancing network traffic across multiple ...
Battery balancing and battery redistribution refer to techniques that improve the available capacity of a battery pack with multiple cells (usually in series) and increase each cell's longevity. [1] A battery balancer or battery regulator is an electrical device in a battery pack that performs battery balancing. [ 2 ]
Power requirements vary by season and time of day. Distribution system designs always take the base load and the peak load into consideration. The transmission system usually does not have a large buffering capability to match loads with generation. Thus generation has to be kept matched to the load, to prevent overloading generation equipment.
For example, in order to match an inductive load into a real impedance, a capacitor needs to be used. If the load impedance becomes capacitive, the matching element must be replaced by an inductor. In many cases, there is a need to use the same circuit to match a broad range of load impedance and thus simplify the circuit design.
Hydro is load following and managing the peaks, with some response from base load thermal. Note that total generation is always greater than the total BPA load because most of the time BPA is a net exporter of energy. The BPA load does not include scheduled energy to other balancing authority areas. [6]