enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Flashback arrestor - Wikipedia

    en.wikipedia.org/wiki/Flashback_arrestor

    Further gas flow in the case of pressure shocks. The entry of air or oxygen into the distribution line or single cylinders. Flashbacks which are the rapid propagation of a flame down the hose. Further gas flow in the event of a burnback. According to the standard DIN EN ISO 5175-1 (formerly EN 730-1) they include a minimum of two safety elements:

  3. Tesla valve - Wikipedia

    en.wikipedia.org/wiki/Tesla_valve

    The flow resistance is defined, analogously to Ohm's law for electrical resistance, [2] as the ratio of applied pressure drop and resulting flow rate: R = Δ p Q {\displaystyle R={\frac {\Delta p}{Q}}} where Δ p {\displaystyle \Delta p} is the applied pressure difference between two ends of the conduit, and Q {\displaystyle Q} the flow rate.

  4. Reduced pressure zone device - Wikipedia

    en.wikipedia.org/wiki/Reduced_pressure_zone_device

    A reduced pressure zone device (RPZD, RPZ, or RPZ valve) is a type of backflow prevention device used to protect water supplies from contamination. RPZDs may also be known as reduced pressure principle (RP), reduced pressure principle backflow prevention devices, [1] [2] reduced pressure zone assemblies (RPZA), [3] or reduced pressure principle ...

  5. Flow distribution in manifolds - Wikipedia

    en.wikipedia.org/wiki/Flow_distribution_in_manifolds

    [4] [5] [6] A generalized model of the flow distribution in channel networks of planar fuel cells. [6] Similar to Ohm's law, the pressure drop is assumed to be proportional to the flow rates. The relationship of pressure drop, flow rate and flow resistance is described as Q 2 = ∆P/R. f = 64/Re for laminar flow where Re is the Reynolds number.

  6. Pressure regulator - Wikipedia

    en.wikipedia.org/wiki/Pressure_regulator

    A typical nominal regulated gauge pressure from a medical oxygen regulator is 3.4 bars (50 psi), for an absolute pressure of approximately 4.4 bar and a pressure ratio of about 4.4 without back pressure, so they will have choked flow in the metering orifices for a downstream (outlet) pressure of up to about 2.3 bar absolute.

  7. Siphon - Wikipedia

    en.wikipedia.org/wiki/Siphon

    Back siphonage is not to be confused with backflow; which is the reversed flow of water from the outlet end to the supply end caused by pressure occurring at the outlet end. [51] Also, building codes usually demand a check valve where the water supply enters a building to prevent backflow into the drinking water system.

  8. Check valve - Wikipedia

    en.wikipedia.org/wiki/Check_valve

    Tilting-disc inconel check valve Check valve symbol on piping and instrumentation diagrams.The arrow shows the flow direction. Vertical lift check valve. A check valve, non-return valve, reflux valve, retention valve, foot valve, or one-way valve is a valve that normally allows fluid (liquid or gas) to flow through it in only one direction.

  9. Crossflow cylinder head - Wikipedia

    en.wikipedia.org/wiki/Crossflow_cylinder_head

    A crossflow head gives better performance than a Reverse-flow cylinder head (though not as good as a uniflow), but the popular explanation put forward for this — that the gases do not have to change direction and hence are moved into and out of the cylinder more efficiently — is a simplification since there is no continuous flow because of valve opening and closing.