enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Palladium (II) chloride - Wikipedia

    en.wikipedia.org/wiki/Palladium(II)_chloride

    Palladium(II) chloride, also known as palladium dichloride and palladous chloride, are the chemical compounds with the formula PdCl 2. PdCl 2 is a common starting material in palladium chemistry – palladium-based catalysts are of particular value in organic synthesis. It is prepared by the reaction of chlorine with palladium metal at high ...

  3. Chemical structure - Wikipedia

    en.wikipedia.org/wiki/Chemical_structure

    The methods by which one can determine the structure of a molecule is called structural elucidation.These methods include: concerning only connectivity of the atoms: spectroscopies such as nuclear magnetic resonance (proton and carbon-13 NMR), various methods of mass spectrometry (to give overall molecular mass, as well as fragment masses).Techniques such as absorption spectroscopy and the ...

  4. Mass spectral interpretation - Wikipedia

    en.wikipedia.org/wiki/Mass_spectral_interpretation

    In the spectrum for toluene for example, the molecular ion peak is located at 92 m/z corresponding to its molecular mass. Molecular ion peaks are also often preceded by an M-1 or M-2 peak resulting from loss of a hydrogen radical or dihydrogen, respectively. Here, M refers to the molecular mass of the compound.

  5. Mass spectrum - Wikipedia

    en.wikipedia.org/wiki/Mass_spectrum

    A mass spectrum is a histogram plot of intensity vs. mass-to-charge ratio (m/z) in a chemical sample, [1] usually acquired using an instrument called a mass spectrometer. Not all mass spectra of a given substance are the same; for example, some mass spectrometers break the analyte molecules into fragments ; others observe the intact molecular ...

  6. Mass spectrometry - Wikipedia

    en.wikipedia.org/wiki/Mass_spectrometry

    Ion mobility spectrometry-mass spectrometry (IMS/MS or IMMS) is a technique where ions are first separated by drift time through some neutral gas under an applied electrical potential gradient before being introduced into a mass spectrometer. [43] Drift time is a measure of the collisional cross section relative to the charge of the ion.

  7. Germanium dichloride - Wikipedia

    en.wikipedia.org/wiki/Germanium_dichloride

    The structure of gas-phase molecular GeCl 2 shows that it is a bent molecule, as predicted by VSEPR theory. [5] The dioxane complex, GeCl 2 ·dioxane, has been used as a source of molecular GeCl 2 for reaction syntheses, as has the in situ reaction of GeCl 4 and Ge metal. GeCl 2 is quite reactive and inserts into many types of chemical bonds. [6]

  8. Mass (mass spectrometry) - Wikipedia

    en.wikipedia.org/wiki/Mass_(mass_spectrometry)

    In mass spectrometry the mass defect is defined as the difference between the exact mass and the nearest integer mass. [21] [22] The Kendrick mass defect is the exact Kendrick mass subtracted from the nearest integer Kendrick mass. [23] Mass defect filtering can be used to selectively detect compounds with a mass spectrometer based on their ...

  9. Molecular geometry - Wikipedia

    en.wikipedia.org/wiki/Molecular_geometry

    Molecular geometry influences several properties of a substance including its reactivity, polarity, phase of matter, color, magnetism and biological activity. [ 1 ] [ 2 ] [ 3 ] The angles between bonds that an atom forms depend only weakly on the rest of molecule, i.e. they can be understood as approximately local and hence transferable ...