enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. File:Ground loop solution - isolation transformer.svg - Wikipedia

    en.wikipedia.org/wiki/File:Ground_loop_solution...

    In this diagram two AC powered electronic components, C1 and C2, are connected by a shielded signal cable S. The ground shield of S, along with the ground wire ("third wire") P in the components' power cord and the building's utility ground wiring G form a ground loop. One of the best ways to prevent such a ground loop is to insert an isolation ...

  3. Three-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Three-phase_electric_power

    A three-wire three-phase circuit is usually more economical than an equivalent two-wire single-phase circuit at the same line-to-ground voltage because it uses less conductor material to transmit a given amount of electrical power. [3] Three-phase power is mainly used directly to power large induction motors, other electric motors and other ...

  4. High-leg delta - Wikipedia

    en.wikipedia.org/wiki/High-leg_delta

    It is used when both single and three-phase power is desired to be supplied from a three phase transformer (or transformer bank). The three-phase power is connected in the delta configuration, and the center point of one phase is grounded. This creates both a split-phase single-phase supply (L1 or L2 to neutral on diagram at right) and three ...

  5. Isolated ground - Wikipedia

    en.wikipedia.org/wiki/Isolated_ground

    The primary reason for the use of isolated grounds (IG) is to provide a noise-free ground return, separate from the equipment grounding (EG) return. The EG circuit includes all of the metal conduit, outlet boxes, and metal enclosures that contain the wiring and must be grounded to provide a safe return path in case of fault currents.

  6. Isolated-phase bus - Wikipedia

    en.wikipedia.org/wiki/Isolated-phase_bus

    The consequences of a two- or three-phase fault between the generator and the first circuit breaker are therefore much more serious and often result in severe damage to the busbars and nearby equipment. Isolated-phase bus is made in ratings from 3000 amperes to 45,000 amperes, and rated for voltages from 5000 volts up to about 35,000 volts.

  7. Delta-wye transformer - Wikipedia

    en.wikipedia.org/wiki/Delta-wye_transformer

    An example delta-wye transformer schematic. A delta-wye transformer is a type of three-phase electric power transformer design that employs delta-connected windings on its primary and wye/star connected windings on its secondary. A neutral wire can be provided on wye output side. It can be a single three-phase transformer, or built from three ...

  8. File:Wiring diagram of 3-phase transfer switch.JPG - Wikipedia

    en.wikipedia.org/wiki/File:Wiring_diagram_of_3...

    Main page; Contents; Current events; Random article; About Wikipedia; Contact us; Donate

  9. Ground and neutral - Wikipedia

    en.wikipedia.org/wiki/Ground_and_neutral

    The neutral conductor of a 3-phase, 4-wire system and the middle conductor of a 2- phase, 3-wire system must have at least 2 separate and distinct earth connections with a minimum of 2 different earth electrodes to have a satisfactory earth resistance; The earth electrodes must be interconnected to reduce earth resistance