Search results
Results from the WOW.Com Content Network
Proximity switches operate by the disturbance of an electromagnetic field, by capacitance, or by sensing a magnetic field. Rarely, a final operating device such as a lamp or solenoid valve is directly controlled by the contacts of an industrial limit switch, but more typically the limit switch is wired through a control relay, a motor contactor ...
Automated diaphragm valves may use pneumatic, hydraulic or electric actuators along with accessories such as solenoid valves, limit switches and positioners. In addition to the well known, two way shut off or throttling diaphragm valve, other types include: Three way zero deadleg valve, sterile access port, block and bleed, valbow and tank ...
An adjustable pressure-limiting valve (commonly abbreviated to APL valve, and also referred to as an expiratory valve, relief valve or spill valve) is a type of flow control valve used in anaesthesiology as part of a breathing system. It allows excess fresh gas flow and exhaled gases to leave the system while preventing ambient air from entering.
An automatic control valve consists of three main parts in which each part exist in several types and designs: Valve actuator – which moves the valve's modulating element, such as ball or butterfly. Valve positioner – which ensures the valve has reached the desired degree of opening. This overcomes the problems of friction and wear.
The valve can use a two-port design to regulate a flow or use a three or more port design to switch flows between ports. Multiple solenoid valves can be placed together on a manifold. Solenoid valves are the most frequently used control elements in fluidics. Their tasks are to shut off, release, dose, distribute or mix fluids.
A check valve, non-return valve, reflux valve, retention valve, foot valve, or one-way valve is a valve that normally allows fluid (liquid or gas) to flow through it in only one direction. [1] Check valves are two-port valves, meaning they have two openings in the body, one for fluid to enter and the other for fluid to leave. There are various ...
For vacuum- or pneumatically operated zone valves, the thermostat usually switches the pressure or vacuum on or off, causing a spring-loaded rubber diaphragm or ball valve to move and actuate the valve. [2] Unlike the switch-monitored electrical zone valves, these valves automatically return to the default position without the application of ...
Choke valve, Butterfly valve used to limit air intake in internal combustion engine. (Not to be confused with choke valves used in industrial flow control, above.) Clapper valve: a type of check valve used in the Siamese fire appliance to allow only one hose to be connected instead of two (the clapper valve blocks the other side from leaking out)