Search results
Results from the WOW.Com Content Network
Ideally the measuring device should not affect the circuit parameters i.e., the internal impedance of the ammeter should be zero (no voltage drop over the ammeter) and the internal impedance of the voltmeter should be infinite (no current through the voltmeter). However, in actual case, ammeters have a low but non zero impedance and voltmeters ...
Class 0.5 is an ANSI C12.20 accuracy class for electric meters with absolute accuracy better than ± 0.5% of the nominal full scale reading. [1] Typically, a class specifies accuracy at a number of points, with the absolute accuracy at lower values being better than the nominal "percentage of full scale" accuracy.
The knee-point voltage of a current transformer is the magnitude of the secondary voltage above which the output current ceases to linearly follow the input current within declared accuracy. In testing, if a voltage is applied across the secondary terminals the magnetizing current will increase in proportion to the applied voltage, until the ...
The reference designator usually consists of one or two letters followed by a number, e.g. C3, D1, R4, U15. The number is sometimes followed by a letter, indicating that components are grouped or matched with each other, e.g. R17A, R17B. The IEEE 315 standard contains a list of Class Designation Letters to use for electrical and electronic ...
The class of natural phenomena related to magnets and magnetic fields. magnetization A property of a material that measures its response to a magnetic field. magnetization current In a transformer, that portion of the current used to support magnetic flux. magnetostatics The study of stationary magnetic fields. magnetostriction
Reference should be made to codes and standards. For example, IEC 60027, and Letter Symbols in Electrical Technology. Here are tables of widely accepted symbols. They are meant to be a guideline: Using the same symbols for the same things in different articles will increase their consistency, making them easier to understand and to improve.
Wire crossover symbols for circuit diagrams. The CAD symbol for insulated crossing wires is the same as the older, non-CAD symbol for non-insulated crossing wires. To avoid confusion, the wire "jump" (semi-circle) symbol for insulated wires in non-CAD schematics is recommended (as opposed to using the CAD-style symbol for no connection), so as to avoid confusion with the original, older style ...
A current transformer (CT) is a series connected measurement device designed to provide a current in its secondary coil proportional to the current flowing in its primary. Current transformers are commonly used in metering and protective relays in the electrical power industry.