Kelvin probe force microscopy (KPFM), also known as surface potential microscopy, is a noncontact variant of atomic force microscopy (AFM). [ 1 ] [ 2 ] [ 3 ] By raster scanning in the x,y plane the work function of the sample can be locally mapped for correlation with sample features.
Scanning probe microscopy (SPM) is a branch of microscopy that forms images of surfaces using a physical probe that scans the specimen. SPM was founded in 1981, with the invention of the scanning tunneling microscope , an instrument for imaging surfaces at the atomic level.
It has long scan times for large sample areas for high resolution imaging. [citation needed] An additional limitation is the predominant orientation of the polarization state of the interrogating light in the near-field of the scanning tip. Metallic scanning tips naturally orient the polarization state perpendicular to the sample surface.
Scanning Hall probe microscope (SHPM) is a variety of a scanning probe microscope which incorporates accurate sample approach and positioning of the scanning tunnelling microscope with a semiconductor Hall sensor. Developed in 1996 by Oral, Bending and Henini, [2] SHPM allows mapping the magnetic induction associated with a sample.
Electrochemical AFM (EC-AFM) is a particular type of Scanning probe microscopy (SPM), which combines the classical Atomic force microscopy (AFM) together with electrochemical measurements. EC-AFM allows to perform in-situ AFM measurements in an electrochemical cell , in order to investigate the actual changes in the electrode surface morphology ...
Scanning vibrating electrode technique was originally introduced to sensitively measure extracellular currents by Jaffe and Nuccitelli in 1974. [1] Jaffe and Nuccitelli then demonstrated the ability of the technique through the measurement of the extracellular currents involved with amputated and re-generating newt limbs, [5] developmental currents of chick embryos, [6] and the electrical ...
Solid-solid conduction. Probe tip to sample. This is the transfer mechanism which yields the thermal scan. Liquid-liquid conduction. When scanning in non-zero humidity, a liquid meniscus forms between the tip and sample. Conduction can occur through this liquid drop. Gas conduction. Heat can be transferred through the edges of the probe tip to ...
The most common scanning mode is constant-height mode, [7] where the tip height is unchanging and is scanned across the surface in the x-y plane. Alternatively, constant distance measurements are possible, which change the z position to maintain the probe to sample distance as the probe is scanned across the surface in the x-y plane.