In liquid chromatography, the mobile phase velocity is taken as the exit velocity, that is, the ratio of the flow rate in ml/second to the cross-sectional area of the ‘column-exit flow path.’ For a packed column, the cross-sectional area of the column exit flow path is usually taken as 0.6 times the cross-sectional area of the column.
Chromatographic peak resolution is given by = + where t R is the retention time and w b is the peak width at baseline. The bigger the time-difference and/or the smaller the bandwidths, the better the resolution of the compounds.
The valley definition defines ΔM as the closest spacing of two peaks of equal intensity with the valley (lowest value of signal) between them less than a specified fraction of the peak height. Typical values are 10% or 50%. The value obtained from a 5% peak width is roughly equivalent to a 10% valley. [1]
The thermal conductivity detector (TCD), also known as a katharometer, is a bulk property detector and a chemical specific detector commonly used in gas chromatography. [1] This detector senses changes in the thermal conductivity of the column eluent and compares it to a reference flow of carrier gas. Since most compounds have a thermal ...
Spring 2009 Class Notes, CHM 5154, Chemical Separations taught by Dr. John Dorsey, Ph.D, Florida State University "Fundamental Resolution Equation". Chemistry LibreTexts. LibreTexts. 29 December 2016 "Appendix 1: Derivation of the Fundamental Resolution Equation". Chemistry LibreTexts. LibreTexts. 30 December 2016
The charged aerosol detector (CAD) is a detector used in conjunction with high-performance liquid chromatography (HPLC) and ultra high-performance liquid chromatography (UHPLC) to measure the amount of chemicals in a sample by creating charged aerosol particles which are detected using an electrometer.
(For instance, if the first column offers a peak capacity (k 1)of 100 for a 10-minute separation, and the second column offers a peak capacity of 5 (k 2) in a 5-second separation, then the combined peak capacity may approach k 1 × k 2 =500, with the total separation time still ~ 10 minutes). 2D separations have been applied to the analysis of ...
A chromatography detector is a device that detects and quantifies separated compounds as they elute from the chromatographic column.These detectors are integral to various chromatographic techniques, such as gas chromatography, [1] liquid chromatography, and high-performance liquid chromatography, [2] and supercritical fluid chromatography [3] among others.