enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Limiting oxygen concentration - Wikipedia

    en.wikipedia.org/wiki/Limiting_oxygen_concentration

    The limiting oxygen concentration (LOC), [1] also known as the minimum oxygen concentration (MOC), [2] is defined as the limiting concentration of oxygen below which combustion is not possible, independent of the concentration of fuel. It is expressed in units of volume percent of oxygen. The LOC varies with pressure and temperature.

  3. Oxygen storage - Wikipedia

    en.wikipedia.org/wiki/Oxygen_storage

    Most humans can function at rest with an oxygen level of 15% at one atmosphere pressure; [1] a fuel such as methane is combustable down to 12% oxygen in nitrogen. A small room of 10 meter 3 has 2.08 meter 3 (2080 liters) or 2.99 kg of oxygen which would occupy 2.62 liters if it was liquid. [2]

  4. Hypoxic air technology for fire prevention - Wikipedia

    en.wikipedia.org/wiki/Hypoxic_air_technology_for...

    Air with low oxygen concentration is produced by hypoxic air generators, also known as air splitting units. There are three different types of hypoxic air generators: membrane-based, PSA-based, and VSA-based. VSA-based hypoxic air generators usually have a lower energy consumption compared to PSA-based and membrane-based generators.

  5. Hypoxia (environmental) - Wikipedia

    en.wikipedia.org/wiki/Hypoxia_(environmental)

    It takes approximately 1 mg of oxygen to break down 1 mg of POC in the environment, and therefore, hypoxia takes place quickly as oxygen is used up quickly to digest POC. About 9% of POC in phytoplankton can be broken down in a single day at 18 °C. Therefore, it takes about eleven days to completely break down phytoplankton. [16]

  6. Oxygen transmission rate - Wikipedia

    en.wikipedia.org/wiki/Oxygen_transmission_rate

    Oxygen transmission rate (OTR) is the measurement of the amount of oxygen gas that passes through a substance over a given period. It is mostly carried out on non-porous materials, where the mode of transport is diffusion, but there are a growing number of applications where the transmission rate also depends on flow through apertures of some description.

  7. Peroxide value - Wikipedia

    en.wikipedia.org/wiki/Peroxide_value

    The peroxide value is defined as the amount of peroxide oxygen per 1 kilogram of fat or oil. Traditionally this was expressed in units of milliequivalents, although in SI units the appropriate option would be in millimoles per kilogram (N.B. 1 milliequivalents = 0.5 millimole; because 1 mEq of O 2 =1 mmol/2 of O 2 =0.5 mmol of O 2, where 2 is valence).

  8. Maximum operating depth - Wikipedia

    en.wikipedia.org/wiki/Maximum_operating_depth

    In which pO 2 is the chosen maximum partial pressure of oxygen in atmospheres absolute and the FO 2 is the fraction of oxygen in the mixture. For example, if a gas contains 36% oxygen (FO 2 = 0.36) and the limiting maximum pO 2 is chosen at 1.4 atmospheres absolute, the MOD in feet of seawater (fsw) [ Notes 1 ] is 33 fsw/atm x [(1.4 ata / 0.36 ...

  9. Equivalent (chemistry) - Wikipedia

    en.wikipedia.org/wiki/Equivalent_(chemistry)

    The solution has 1 mole or 1 equiv Na +, 1 mole or 2 equiv Ca 2+, and 3 mole or 3 equiv Cl −. An earlier definition, used especially for chemical elements , holds that an equivalent is the amount of a substance that will react with 1 g (0.035 oz) of hydrogen , 8 g (0.28 oz) of oxygen , or 35.5 g (1.25 oz) of chlorine —or that will displace ...