Search results
Results from the WOW.Com Content Network
The limiting oxygen concentration (LOC), [1] also known as the minimum oxygen concentration (MOC), [2] is defined as the limiting concentration of oxygen below which combustion is not possible, independent of the concentration of fuel. It is expressed in units of volume percent of oxygen. The LOC varies with pressure and temperature.
Most humans can function at rest with an oxygen level of 15% at one atmosphere pressure; [1] a fuel such as methane is combustable down to 12% oxygen in nitrogen. A small room of 10 meter 3 has 2.08 meter 3 (2080 liters) or 2.99 kg of oxygen which would occupy 2.62 liters if it was liquid. [2]
Oxygen transmission rate (OTR) is the measurement of the amount of oxygen gas that passes through a substance over a given period. It is mostly carried out on non-porous materials, where the mode of transport is diffusion, but there are a growing number of applications where the transmission rate also depends on flow through apertures of some description.
1 Nm 3 of any gas (measured at 0 °C and 1 atmosphere of absolute pressure) equals 37.326 scf of that gas (measured at 60 °F and 1 atmosphere of absolute pressure). 1 kmol of any ideal gas equals 22.414 Nm 3 of that gas at 0 °C and 1 atmosphere of absolute pressure ... and 1 lbmol of any ideal gas equals 379.482 scf of that gas at 60 °F and ...
In environmental chemistry, the chemical oxygen demand (COD) is an indicative measure of the amount of oxygen that can be consumed by reactions in a measured solution.It is commonly expressed in mass of oxygen consumed over volume of solution, which in SI units is milligrams per liter (mg/L).
Oxygen equivalent compares the relative amount of oxygen available for respiration at a variable pressure to that available at SATP.As external respiration depends on the exchange of gases due to partial pressures across a semipermeable membrane and normally occurs at SATP, an oxygen equivalent may aid in recognizing and managing variable oxygen availability during procedures such as ...
Get AOL Mail for FREE! Manage your email like never before with travel, photo & document views. Personalize your inbox with themes & tabs. You've Got Mail!
UL 67377 Oxygen Reduction Fire Prevention System Units [10] BSI PAS 95:2011 - Hypoxic air fire prevention systems. Specification [4] VdS 3527en:2007 - Inerting and Oxygen Reduction Systems, Planning and Installation [11] Austrian Standards International. ÖNORM F 3073: Planning, engineering, assembly, commissioning and servicing of oxygen ...