Search results
Results from the WOW.Com Content Network
The test piece is attached in series with the pump and measuring element and air is pumped through the whole system. Therefore, all the air passing through the metering element also passes through the test piece. Because the volumetric flow rate through the metering element is known and the flow through the test piece is the same, it is also known.
The tests for the other three installations namely, good flow conditions, partly closed valve and highly disturbed flow) may be performed for = 0.67, and the results for other (i ratios predicted from the () correlation. Otherwise, the tests should be performed for a range of p ratios between 0.20 and 0.75.
All mass flow controllers have an inlet port, an outlet port, a mass flow sensor and a proportional control valve. The MFC is fitted with a closed loop control system which is given an input signal by the operator (or an external circuit/computer) that it compares to the value from the mass flow sensor and adjusts the proportional valve ...
Skinner box. An operant conditioning chamber (also known as a Skinner box) is a laboratory apparatus used to study animal behavior. The operant conditioning chamber was created by B. F. Skinner while he was a graduate student at Harvard University. The chamber can be used to study both operant conditioning and classical conditioning. [1] [2]
The Casablanca-class escort carrier, the most prolific aircraft carrier design in history, used two 5-cylinder Skinner Unaflow engines, but these were not steeple compounds. A non-compound Skinner Uniflow remained in service until 2013 in the Great Lakes cement carrier SS St. Marys Challenger, installed when the vessel was re-powered in 1950 ...
A simplified version of the definition is: The k v factor of a valve indicates "The water flow in m 3 /h, at a pressure drop across the valve of 1 kgf/cm 2 when the valve is completely open. The complete definition also says that the flow medium must have a density of 1000 kg/m 3 and a kinematic viscosity of 10 −6 m 2 /s, e.g. water. [clarify]
A process to perform a water flow test is explained in the model fire codes as published by NFPA (National Fire Protection Association). If a water supply source is considered weak compared to what is required by the sprinkler system design hydraulic calculation , the water pressure can be boosted by means of a fire pump .
These types of valves are also known as automatic control valves. The hydraulic actuators respond to changes of pressure or flow and will open/close the valve. Automatic control valves do not require an external power source, meaning that the fluid pressure is enough to open and close them.