enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Useful conversions and formulas for air dispersion modeling

    en.wikipedia.org/wiki/Useful_conversions_and...

    0.1 × ( 12 ÷ 8 ) = 0.15 grain per dscf when corrected to a gas having a specified reference CO 2 content of 12 volume %. Notes: Although ppmv and grains per dscf have been used in the above examples, concentrations such as ppbv (i.e., parts per billion by volume), volume percent, grams per dscm and many others may also be used.

  3. Module:Convert/documentation/conversion data - Wikipedia

    en.wikipedia.org/wiki/Module:Convert/...

    The conversion procedure for some units (for example, the Mach unit of speed) are built into Module:Convert as they are too complex to be specified in a table. That is indicated by entering a code (which must be the same as used in the module) in the Extra column.

  4. Air pollutant concentrations - Wikipedia

    en.wikipedia.org/wiki/Air_pollutant_concentrations

    As an example, a measured NO x concentration of 45 ppmv in a dry gas having 5 volume % O 2 is: 45 × ( 20.9 - 3 ) ÷ ( 20.9 - 5 ) = 50.7 ppmv of NO x. when corrected to a dry gas having a specified reference O 2 content of 3 volume %. Note: The measured gas concentration C m must first be corrected to a dry basis before using the above equation.

  5. Help:Convert - Wikipedia

    en.wikipedia.org/wiki/Help:Convert

    By default, the output value is rounded to adjust its precision to match that of the input. An input such as 1234 is interpreted as 1234 ± 0.5, while 1200 is interpreted as 1200 ± 50, and the output value is displayed accordingly, taking into account the scale factor used in the conversion.

  6. Density of air - Wikipedia

    en.wikipedia.org/wiki/Density_of_air

    At 101.325 kPa (abs) and 20 °C (68 °F), air has a density of approximately 1.204 kg/m 3 (0.0752 lb/cu ft), according to the International Standard Atmosphere (ISA). At 101.325 kPa (abs) and 15 °C (59 °F), air has a density of approximately 1.225 kg/m 3 (0.0765 lb/cu ft ), which is about 1 ⁄ 800 that of water , according to the ...

  7. Total dissolved solids - Wikipedia

    en.wikipedia.org/wiki/Total_dissolved_solids

    where TDS is expressed in mg/L and EC is the electrical conductivity in microsiemens per centimeter at 25 °C. The conversion factor k e varies between 0.55 and 0.8. [5] Some TDS meters use an electrical conductivity measurement to the ppm using the above formula. Regarding units, 1 ppm indicates 1 mg of dissolved solids per 1,000 g of water. [6]

  8. Template:Convert - Wikipedia

    en.wikipedia.org/wiki/Template:Convert

    Converts measurements to other units. Template parameters [Edit template data] This template prefers inline formatting of parameters. Parameter Description Type Status Value 1 The value to convert. Number required From unit 2 The unit for the provided value. Suggested values km2 m2 cm2 mm2 ha sqmi acre sqyd sqft sqin km m cm mm mi yd ft in kg g mg lb oz m/s km/h mph K C F m3 cm3 mm3 L mL cuft ...

  9. Equivalent concentration - Wikipedia

    en.wikipedia.org/wiki/Equivalent_concentration

    For example, sulfuric acid (H 2 SO 4) is a diprotic acid. Since only 0.5 mol of H 2 SO 4 are needed to neutralize 1 mol of OH −, the equivalence factor is: f eq (H 2 SO 4) = 0.5. If the concentration of a sulfuric acid solution is c(H 2 SO 4) = 1 mol/L, then its normality is 2 N. It can also be called a "2 normal" solution.