  1. Results from the WOW.Com Content Network
  2. National Electrical Code - Wikipedia

    en.wikipedia.org/wiki/National_Electrical_Code

    A full-load wire does heat up slightly due to the metallic resistance of the wire, but this wire heating is factored into the cable's temperature rating. (NEC 310.10) [12] The NEC specifies acceptable numbers of conductors in crowded areas such as inside conduit, referred to as the fill rating.

  3. Electrical wiring in North America - Wikipedia

    en.wikipedia.org/wiki/Electrical_wiring_in_North...

    In both those instances the white wire should be identified as being hot, usually with black tape inside junction boxes. The neutral wire is identified by gray or white insulated wire, perhaps using stripes or markings. With lamp cord wire the ribbed wire is the neutral, and the smooth wire is the hot. NEC 2008 400.22(f) allows surface marking ...

  4. Electrical conduit - Wikipedia

    en.wikipedia.org/wiki/Electrical_conduit

    Galvanized rigid conduit (GRC) is galvanized steel tubing, with a tubing wall that is thick enough to allow it to be threaded. Its common applications are in commercial and industrial construction. [1] It is designed to protect wire and connectors. Intermediate metal conduit (IMC) is a steel tubing heavier than EMT but lighter than RMC. It may ...

  5. Electrical wiring - Wikipedia

    en.wikipedia.org/wiki/Electrical_wiring

    The first rubber-insulated cables for US building wiring were introduced in 1922 with US patent 1458803, Burley, Harry & Rooney, Henry, "Insulated electric wire", issued 1923-06-12, assigned to Boston Insulated Wire and Cable . These were two or more solid copper electrical wires with rubber insulation, plus woven cotton cloth over each ...

  6. Service drop - Wikipedia

    en.wikipedia.org/wiki/Service_drop

    A 240/120 V split-phase service drop providing power to a residence in USA. The three wires from the utility pole enter through a weatherhead (top) into a vertical conduit, which routes them to the electric meter (bottom). From there they pass through the wall of the house to the electric panel and Main Fuses or Circuit Breakers inside.

  7. Thermoplastic-sheathed cable - Wikipedia

    en.wikipedia.org/wiki/Thermoplastic-sheathed_cable

    This does not include the uninsulated ground wire. For instance, if the cable lists "12-2 AWG", it means there are two insulated 12-gauge wires (a black and a white wire), plus a ground wire. If the label says "12-3", this cable has four conductors—three 12-gauge insulated wires and a bare copper ground wire. [5]