Electrospray ionization (ESI) is a technique used in mass spectrometry to produce ions using an electrospray in which a high voltage is applied to a liquid to create an aerosol. It is especially useful in producing ions from macromolecules because it overcomes the propensity of these molecules to fragment when ionized.
Taylor's derivation is based on two assumptions: (1) that the surface of the cone is an equipotential surface and (2) that the cone exists in a steady state equilibrium. To meet both of these criteria the electric field must have azimuthal symmetry and have R {\displaystyle {\sqrt {R}}\,} dependence to counter the surface tension to produce the ...
The figure shows the main components of an APPI source: a nebulizer probe which can be heated to 350–500 °C, an ionization region with a VUV photon source, and an ion-transfer region under intermediate pressure that introduces ions into the MS analyzer. The analyte(s) in solution from the HPLC flows into the nebulizer at a flow rate that can ...
Electrostatic spray ionization (ESTASI) is an ambient ionization method for mass spectrometry (MS) analysis of samples located on a flat or porous surface, or inside a microchannel. It was developed in 2011 by Professor Hubert H. Girault ’s group at the École Polytechnique Fédérale de Lausanne (EPFL) in Switzerland. [ 1 ]
A close-up of an electrospray device, with emitter tip in foreground pointing to the right. The jet of ionised spray is visible within the image. To simplify the discussion, the following paragraphs will address the case of a positive electrospray with the high voltage applied to a metallic emitter.
Ambient ionization techniques are attractive for many samples for their high tolerance to complex mixtures and for fast testing. EESI has been employed for the rapid characterization of living objects, [ 10 ] native proteins , [ 11 ] and metabolic biomarkers .
Desorption electrospray ionization (DESI) is an ambient ionization technique that can be coupled to mass spectrometry (MS) for chemical analysis of samples at atmospheric conditions. Coupled ionization sources-MS systems are popular in chemical analysis because the individual capabilities of various sources combined with different MS systems ...
Secondary electrospray ionization mechanism diagram. In the early days of SESI, two ionization mechanisms were under debate.: the droplet-vapor interaction model postulates that vapors are adsorbed in the electrospray ionization (ESI) droplets, and then reemitted as the droplet shrinks, just as regular liquid phase analytes are produced in electrospray ionization; on the other hand, the ion ...