  1. Results from the WOW.Com Content Network
  2. Load-loss factor - Wikipedia

    en.wikipedia.org/wiki/Load-loss_factor

    Multiple empirical formulae exist that relate the loss factor to the load factor (Dickert et al. in 2009 listed nine [5]). Similarly, the ratio between the average and the peak current is called form coefficient k [ 6 ] or peak responsibility factor k , [ 7 ] its typical value is between 0.2 to 0.8 for distribution networks and 0.8 to 0.95 for ...

  3. Losses in electrical systems - Wikipedia

    en.wikipedia.org/wiki/Losses_in_electrical_systems

    In an electrical or electronic circuit or power system part of the energy in play is dissipated by unwanted effects, including energy lost by unwanted heating of resistive components (electricity is also used for the intention of heating, which is not a loss), the effect of parasitic elements (resistance, capacitance, and inductance), skin effect, losses in the windings and cores of ...

  4. Forced outage - Wikipedia

    en.wikipedia.org/wiki/Forced_outage

    Forced outage rate (FOR or FOAR) of a power station unit is the probability that the unit will not be available for service when required.. FOR is defined as the number of hours the unit is on forced outage over the total number of hours in a year (which is the sum of hours the power station is available for service and hours the power station is in forced outage).

  5. Energy conversion efficiency - Wikipedia

    en.wikipedia.org/wiki/Energy_conversion_efficiency

    The energy efficiency of a fuel cell is generally between 40 and 60%; however, if waste heat is captured in a cogeneration scheme, efficiencies of up to 85% can be obtained. [24] World average fossil fuel electricity generation power plant as of 2008 [25] Chemical to electrical Gross output 39%, Net output 33% Electricity storage: Lithium-ion ...

  6. Load factor (electrical) - Wikipedia

    en.wikipedia.org/wiki/Load_factor_(electrical)

    In electrical engineering the load factor is defined as the average load divided by the peak load in a specified time period. [1] It is a measure of the utilization rate, or efficiency of electrical energy usage; a high load factor indicates that load is using the electric system more efficiently, whereas consumers or generators that underutilize the electric distribution will have a low load ...

  7. Mathematics of three-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Mathematics_of_three-phase...

    The plotted line represents the variation of instantaneous voltage (or current) with respect to time. This cycle repeats with a frequency that depends on the power system. In electrical engineering, three-phase electric power systems have at least three conductors carrying alternating voltages that are offset in time by one-third of the period ...

  8. Electrical efficiency - Wikipedia

    en.wikipedia.org/wiki/Electrical_efficiency

    An electronic amplifier that delivers 10 watts of power to its load (e.g., a loudspeaker), while drawing 20 watts of power from a power source is 50% efficient. (10/20 × 100 = 50%) Electric kettle: more than 90% [citation needed] (comparatively little heat energy is lost during the 2 to 3 minutes a kettle takes to boil water).

  9. Value of lost load - Wikipedia

    en.wikipedia.org/wiki/Value_of_lost_load

    The Value of Lost Load (VoLL) is the estimated amount that customers receiving electricity with firm contracts would be willing to pay to avoid a disruption in their electricity service. [1] The value of these losses can be expressed as a customer damage function (CDF). A CDF is defined [2] as: Loss ($/kW) = ƒ (duration, season, time of day ...