Pacific Electric Upland–San Bernardino: Operated 1914–1950. 600 V in city limits California: Sacramento Northern Railway: Operated 1910–1936. Converted to 1,500 V. The southern division was built by the Oakland, Antioch and Eastern Railway. East Bay, California: East Bay Electric Lines: 1911–1941 Oregon: Oregon Electric Railway: 1912–1945
Power is supplied to the SWER line by an isolating transformer of up to 300 kVA. This transformer isolates the grid from ground or earth. The voltage changes due to the transition from line-to-line to line-to-earth, typically reducing a 22 kV grid to 12.7 kV SWER or a 33 kV grid to 19.1 kV SWER.
A third rail, also known as a live rail, electric rail or conductor rail, is a method of providing electric power to a railway locomotive or train, through a semi-continuous rigid conductor placed alongside or between the rails of a railway track.
A "transformer bank", widely used in North America: three single-phase transformers connected to make a 3-phase transformer. The low-voltage secondary windings are attached to three or four terminals on the transformer's side. In North American residences and small businesses, the secondary is often the split-phase 120/240-volt system. The 240 ...
A network protector is a type of electric protective device used in electricity distribution systems. The network protector automatically disconnect its associated distribution transformer from the secondary network when the power starts flowing in reverse direction.
Switched-mode power supplies have become widespread in the early twenty-first century; they are smaller and lighter than the once-universal transformer converters, and are often designed to work from AC mains at any voltage between 100 and 250 V. Additionally, because they are typically rectified to operate at a DC voltage, they are minimally ...
A transformer supplying a three-wire distribution system has a single-phase input (primary) winding. The output (secondary) winding has a center tap connected to a grounded neutral. As shown in Fig. 1, either end to center has half the voltage of end-to-end. Fig. 2 illustrates the phasor diagram
A single-phase, three-winding converter transformer. The converter transformers step up the voltage of the AC supply network. Using a star-to-delta or "wye-delta" connection of the transformer windings, the converter can operate with 12 pulses for each cycle in the AC supply, which eliminates numerous harmonic current components. The insulation ...