Search results
Results from the WOW.Com Content Network
A strap footing is a component of a building's foundation. It is a type of combined footing, [1] consisting of two or more column footings connected by a concrete beam. This type of beam is called a strap beam. It is used to help distribute the weight of either heavily or eccentrically loaded column footings to adjacent footings. [2]
A combined footing is typically utilized when the spacing of the columns is too restricted such that if isolated footing were used, they would overlap one another. Also, when property lines make isolated footings eccentrically loaded, combined footings are preferred. When the load among the columns is equal, the combined footing may be rectangular.
[6]: 3 Rudolph's design was "an A-frame with terraced floors and angled walls and windows" [7] with "an eccentrically loaded trapezoidal steel frame with columns inclined at 22.5 degrees". [8] The design used concrete panels to create "an elongated hexagonal module that gives the building a strong horizontal reading on the long elevations". [5]
The design of most classical columns incorporates entasis (the inclusion of a slight outward curve in the sides) plus a reduction in diameter along the height of the column, so that the top is as little as 83% of the bottom diameter. This reduction mimics the parallax effects which the eye expects to see, and tends to make columns look taller ...
Shallow foundations of a house versus the deep foundations of a skyscraper. Foundation with pipe fixtures coming through the sleeves. In engineering, a foundation is the element of a structure which connects it to the ground or more rarely, water (as with floating structures), transferring loads from the structure to the ground.
Stuart [1] was the first pioneer to study the interference phenomenon of closely spaced surface strip footing. He examined the effect of footing interference on ultimate bearing capacity of strip footings by theoretical analysis using limit equilibrium method, assuming a non-linear failure surface wherein the cross-section composed of logarithmic spiral and straight line portion tangent to the ...
Accordingly, special concentrically or eccentrically braced frames were later developed with extensive design requirements, and are frequently used in areas of high seismic risk. The purpose of the concentrically- or eccentrically-braced design is to ensure adequate ductility (i.e., to stretch without breaking suddenly).
Stress distribution in soil is a function of the type of soil, the relative rigidity of the soil and the footing, and the depth of foundation at level of contact between footing and soil. [1] The estimation of vertical stresses at any point in a soil mass due to external loading is essential to the prediction of settlements of buildings ...