enow.com Web Search

  1. Ads

    related to: 120 240 3 phase 4 wire

Search results

  1. Results from the WOW.Com Content Network
  2. High-leg delta - Wikipedia

    en.wikipedia.org/wiki/High-leg_delta

    Current practice is to give separate services for single-phase and three-phase loads, e.g., 120 V split-phase (lighting etc.) and 240 V to 600 V three-phase (for large motors). However, many jurisdictions forbid more than one class for a premises' service, and the choice may come down to 120/240 V split-phase, 208 V single-phase or three-phase ...

  3. Three-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Three-phase_electric_power

    Three-phase transformer with four-wire output for 208Y/120 volt service: one wire for neutral, others for A, B and C phases. Three-phase electric power (abbreviated 3ϕ [1]) is a common type of alternating current (AC) used in electricity generation, transmission, and distribution. [2]

  4. Electrical wiring in North America - Wikipedia

    en.wikipedia.org/wiki/Electrical_wiring_in_North...

    Lighting and general purpose receptacles are at 120 volts AC, with larger devices fed by three wire single-phase circuits at 240 volts. In commercial construction, three-phase circuits are often used. Common 3 phase configurations within a building are 208v/120 wye, 120/240 center tapped delta and 480v/277v wye. Lighting is usually fed by 277 V ...

  5. Split-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Split-phase_electric_power

    In Europe, three-phase 230/400 V is most commonly used. However, 130/225 V, three-wire, two-phase electric power discontinued systems called B1 are used to run old installations in small groups of houses when only two of the three-phase high-voltage conductors are used. The phase shift in Europe is 120°, as is the case with three-phase current.

  6. Electric power distribution - Wikipedia

    en.wikipedia.org/wiki/Electric_power_distribution

    Most of the Americas use 60 Hz AC, the 120/240 volt split-phase system domestically and three phase for larger installations. North American transformers usually power homes at 240 volts, similar to Europe's 230 volts. It is the split-phase that allows use of 120 volts in the home. Japan's utility frequencies are 50 Hz and 60 Hz.

  7. NEMA connector - Wikipedia

    en.wikipedia.org/wiki/NEMA_connector

    NEMA L14 are three-pole and ground connectors rated for 125/250 V. Intended for three-pole, four-wire hot-hot-neutral-ground circuits with a nominal supply voltages of 240 or 208 V hot-to-hot and 120 V hot-to-neutral.

  1. Ads

    related to: 120 240 3 phase 4 wire