A fire-resistance rating typically means the duration for which a passive fire protection system can withstand a standard fire resistance test. This can be quantified simply as a measure of time, or it may entail other criteria, involving evidence of functionality or fitness for purpose.
Circuit integrity fireproofing of cable trays using calcium silicate board system Circuit integrity fireproofing of cable trays Fire-resistant cables MI cables fastened into junction box that has not been fireproofed. Circuit integrity describes the extent of a fire's effect on an electrical circuit's operation. It is a form of fire-resistance ...
UL-94 is now harmonized with IEC 60695-11-10 and 60695-11-20 and ISO 9772 and 9773. [2] The VW-1 (vertical wire burn) rating is sometimes erroneously associated with UL 94, but it (and some other flammability tests) is described by UL 1581 (Reference Standard for Electrical Wires, Cables, and Flexible Cords).
Fire-resistance rated door, with wire mesh glass vision panel Industrial grade fire door rated to hydrocarbon curve and blast resistance Double fire door immediately after 3-hour fire test inside a 4-hour rated Durasteel wall Double fire door after 3-hour fire test in a 4-hour Durasteel wall, during successful 45PSI (3.1 bar) hose stream test leading to a UL Listing [1]
An insulation resistance test (IR test) measures the electrical resistance of insulation by applying a voltage between two locations, and measuring the resultant current flow. Proper safety precautions must be taken when doing this test, such as exclusion zones, making sure no wires are exposed, and personal protective equipment is worn.
A firestop or fire-stopping is a form of passive fire protection that is used to seal around openings and between joints in a fire-resistance-rated wall or floor assembly. Firestops are designed to maintain the fire-resistance rating of a wall or floor assembly intended to impede the spread of fire and smoke. [1]
Weather-resistant. Protects against falling dirt and windblown dust, against weather hazards such as rain, sleet and snow, and is undamaged by the formation of ice. Used outdoors on ship docks, in construction work, and in tunnels and subways. 3R: As 3, but omits protection against windblown dust. 3S: As 3, but also operable when laden with ice.
UL 1709 Rapid Rise Fire Tests of Protection Materials for Structural Steel UL 2085 Protected Aboveground Tanks for Flammable and Combustible Liquids EN 16034 Pedestrian doorsets, industrial, commercial, garage doors and openable windows – Product standard, performance characteristics – Fire resisting and/or smoke control characteristics