enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Cooling load temperature difference calculation method

    en.wikipedia.org/wiki/Cooling_load_temperature...

    The respective tables of data were generally developed by using the more complex transfer function method to determine the various cooling loads for different types of heating. [ 2 ] [ 3 ] The results gained by doing so are then normalized for each type of heat gain used for the tables, CLTD, CLF, and SCL.

  3. United States building energy codes - Wikipedia

    en.wikipedia.org/wiki/United_States_building...

    [4] The model code, IECC, and the standard, ASHRAE 90.1, apply to commercial buildings. [5] [4] [6] The IECC references several ASHRAE Standards, in particular, ASHRAE 90.1 for commercial building construction. [22] Being a part of the ICC’s collection of model codes, the IECC is revised annually and published in full-form every three years.

  4. ASHRAE 55 - Wikipedia

    en.wikipedia.org/wiki/ASHRAE_55

    It is defined as per unit of skin surface area which equals to 58.2 W/m 2 (18.4 Btu/h·ft 2). This is the energy produced from a unit skin surface area of an average person seated at rest. [1] ANSI/ASHRAE Standard 55 provides a table of metabolic rate of different continuous activities

  5. International Green Construction Code - Wikipedia

    en.wikipedia.org/wiki/International_Green...

    The IGCC will reference the Public Version 1.0/ ANSI/ASHRAE/USGBC/IES Standard 189.1-2009 for the Design of High-Performance Green Buildings, Except Low-Rise Residential Buildings, as an alternative jurisdictional compliance option within the IGCC. The participants in designing this Standard also voiced their support for the new IGCC and its ...

  6. Ventilation (architecture) - Wikipedia

    en.wikipedia.org/wiki/Ventilation_(architecture)

    The 1989 ASHRAE standard (Standard 62–89) states that appropriate ventilation guidelines are 20 CFM (9.2 L/s) per person in an office building, and 15 CFM (7.1 L/s) per person for schools, while 2004 Standard 62.1-2004 has lower recommendations again (see tables below). ANSI/ASHRAE (Standard 62–89) speculated that "comfort (odor) criteria ...

  7. Infiltration (HVAC) - Wikipedia

    en.wikipedia.org/wiki/Infiltration_(HVAC)

    The infiltration rate is the volumetric flow rate of outside air into a building, typically in cubic feet per minute (CFM) or liters per second (LPS). The air exchange rate, (I), is the number of interior volume air changes that occur per hour, and has units of 1/h. The air exchange rate is also known as air changes per hour (ACH).

  8. Radiant heating and cooling - Wikipedia

    en.wikipedia.org/wiki/Radiant_heating_and_cooling

    The norm ISO 7730 and the ASHRAE 55 standard give the predicted percentage of dissatisfied occupants (PPD) as a function of the radiant temperature asymmetry and specify the acceptable limits. In general, people are more sensitive to asymmetric radiation caused by a warm ceiling than that caused by hot and cold vertical surfaces.

  9. ASHRAE Handbook - Wikipedia

    en.wikipedia.org/wiki/ASHRAE_Handbook

    The ASHRAE Handbook is the four-volume flagship publication of the nonprofit technical organization ASHRAE (American Society of Heating, Refrigerating and Air-Conditioning Engineers [a]). This Handbook is considered the most comprehensive and authoritative repository of practical knowledge on the various topics that form the field of heating ...