  1. Results from the WOW.Com Content Network
  2. Friction loss - Wikipedia

    en.wikipedia.org/wiki/Friction_loss

    The following table gives flow rate Q such that friction loss per unit length Δp / L (SI kg / m 2 / s 2) is 0.082, 0.245, and 0.816, respectively, for a variety of nominal duct sizes. The three values chosen for friction loss correspond to, in US units inch water column per 100 feet, 0.01, .03, and 0.1.

  3. Atkinson resistance - Wikipedia

    en.wikipedia.org/wiki/Atkinson_resistance

    This may have been a step too far, as most of his successors chose to give values of Atkinson resistance in terms of atkinsons per unit length (often 100 or 1,000 yards). The term 1 / 2 ρ {\displaystyle 1/2\rho } was incorporated, which later authors definitely considered a step too far (e.g. McPherson, 1988).

  4. Ductwork airtightness - Wikipedia

    en.wikipedia.org/wiki/Ductwork_airtightness

    There are two major systems to classify ductwork airtightness, one based on European standards, the other based on ASHRAE standard 90.1-2010.Both are based on the leakage airflow rate at a given ductwork pressure divided by the product of the ductwork surface area and the same ductwork pressure raised to the power 0.65.

  5. Darcy–Weisbach equation - Wikipedia

    en.wikipedia.org/wiki/Darcy–Weisbach_equation

    where the pressure loss per unit length ⁠ Δp / L ⁠ (SI units: Pa/m) is a function of: ρ {\displaystyle \rho } , the density of the fluid (kg/m 3 ); D H {\displaystyle D_{H}} , the hydraulic diameter of the pipe (for a pipe of circular section, this equals D ; otherwise D H = 4A/P for a pipe of cross-sectional area A and perimeter P ) (m);

  6. Flow coefficient - Wikipedia

    en.wikipedia.org/wiki/Flow_coefficient

    The flow is proportional to the absolute inlet pressure, so the flow in scfm would equal the C v flow coefficient if the inlet pressure were reduced to 2 psia and the outlet were connected to a vacuum with less than 1 psi absolute pressure (1.0 scfm when C v = 1.0, 2 psia input).

  7. Darcy friction factor formulae - Wikipedia

    en.wikipedia.org/wiki/Darcy_friction_factor_formulae

    Before choosing a formula it is worth knowing that in the paper on the Moody chart, Moody stated the accuracy is about ±5% for smooth pipes and ±10% for rough pipes. If more than one formula is applicable in the flow regime under consideration, the choice of formula may be influenced by one or more of the following:

  8. Duct (flow) - Wikipedia

    en.wikipedia.org/wiki/Duct_(flow)

    An air handling unit with vibration isolator (3) A duct system often begins at an air handler. The blowers in the air handler can create substantial vibration, and the large area of the duct system would transmit this noise and vibration to the inhabitants of the building. To avoid this, vibration isolators (flexible sections) are normally ...

  9. Process duct work - Wikipedia

    en.wikipedia.org/wiki/Process_Duct_Work

    The air in process duct work may be at ambient conditions or may operate at up to 900 °F (482 °C). Process ductwork varies in size from 2 ft diameter to 20 ft diameter or to perhaps 20 ft by 40 ft rectangular.