Search results
Results from the WOW.Com Content Network
The magnitude of overshoot depends on time through a phenomenon called "damping." See illustration under step response. Overshoot often is associated with settling time, how long it takes for the output to reach steady state; see step response. Also see the definition of overshoot in a control theory context.
The definition of a closed loop control system according to the British Standards Institution is "a control system possessing monitoring feedback, the deviation signal formed as a result of this feedback being used to control the action of a final control element in such a way as to tend to reduce the deviation to zero." [12]
In the case of linear dynamic systems, much can be inferred about the system from these characteristics. Below the step response of a simple two-pole amplifier is presented, and some of these terms are illustrated. In LTI systems, the function that has the steepest slew rate that doesn't create overshoot or ringing is the Gaussian function.
In control theory, overshoot refers to an output exceeding its final, steady-state value. [13] For a step input, the percentage overshoot (PO) is the maximum value minus the step value divided by the step value. In the case of the unit step, the overshoot is just the maximum value of the step response minus one.
Within modern distributed control systems and programmable logic controllers, it is much easier to prevent integral windup by either limiting the controller output, limiting the integral to produce feasible output, [5] or by using external reset feedback, which is a means of feeding back the selected output to the integral circuit of all ...
Therefore, we design control into systems. This requires more thought in the systems design but allows more flexibility of operations and makes it possible to operate a system using unpredictable components and undetermined input. Still, the design and effective operation of control are not without problems.
The definition of a closed loop control system according to the British Standards Institution is "a control system possessing monitoring feedback, the deviation signal formed as a result of this feedback being used to control the action of a final control element in such a way as to tend to reduce the deviation to zero." [2]
Departure of such a variable from its setpoint is one basis for error-controlled regulation using negative feedback for automatic control. [3] A setpoint can be any physical quantity or parameter that a control system seeks to regulate, such as temperature, pressure, flow rate, position, speed, or any other measurable attribute.