where TDS is expressed in mg/L and EC is the electrical conductivity in microsiemens per centimeter at 25 °C. The conversion factor k e varies between 0.55 and 0.8. [5] Some TDS meters use an electrical conductivity measurement to the ppm using the above formula. Regarding units, 1 ppm indicates 1 mg of dissolved solids per 1,000 g of water. [6]
For example, the conversion factor between a mass fraction of 1 ppb and a mole fraction of 1 ppb is about 4.7 for the greenhouse gas CFC-11 in air (Molar mass of CFC-11 / Mean molar mass of air = 137.368 / 28.97 = 4.74). For volume fraction, the suffix "V" or "v" is sometimes appended to the parts-per notation (e.g. ppmV, ppbv, pptv).
The grain per gallon (gpg) is a unit of water hardness defined as 1 grain (64.8 milligrams) of calcium carbonate dissolved in 1 US gallon of water (3.785412 L). It translates into 1 part in about 58,000 parts of water or 17.1 parts per million (ppm). Also called Clark degree (in terms of an imperial gallon).
1 mmol/L is equivalent to 100.09 mg/L CaCO 3 or 40.08 mg/L Ca 2+. A degree of General Hardness ( dGH or 'German degree' (°dH, deutsche Härte )) is defined as 10 mg/L CaO or 17.848 ppm. A Clark degree (°Clark) or English degree (°e or e) is defined as one grain (64.8 mg) of CaCO 3 per Imperial gallon (4.55 litres) of water, equivalent to 14. ...
Normality is defined as the number of gram or mole equivalents of solute present in one liter of solution.The SI unit of normality is equivalents per liter (Eq/L). = where N is normality, m sol is the mass of solute in grams, EW sol is the equivalent weight of solute, and V soln is the volume of the entire solution in liters.
Due to relatively high concentrations in the aqueous stock solutions (cf. Tables 1 and 2) the Hoagland solution is very good for the growth of plants with lower nutrient demands as well, such as lettuce and aquatic plants, with the further dilution of the preparation to 1 ⁄ 4 or 1 ⁄ 5 of the modified solution.
Atmospheric pollutant concentrations expressed as mass per unit volume of atmospheric air (e.g., mg/m 3, μg/m 3, etc.) at sea level will decrease with increasing altitude because the atmospheric pressure decreases with increasing altitude.
TSS of a water or wastewater sample is determined by pouring a carefully measured volume of water (typically one litre; but less if the particulate density is high, or as much as two or three litres for very clean water) through a pre-weighed filter of a specified pore size, then weighing the filter again after the drying process that removes all water on the filter.