enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Tap changer - Wikipedia

    en.wikipedia.org/wiki/Tap_changer

    However, a transformer may include a tap changer on each winding if there are advantages to do so. For example, in power distribution networks, a large step-down transformer may have an off-load tap changer on the primary winding and an on load automatic tap changer on the secondary winding or windings. The high voltage tap is set to match long ...

  3. Tap converter - Wikipedia

    en.wikipedia.org/wiki/Tap_converter

    Both linear spacing and power-of-two-style Vernier spacing can be employed in establishing the tap positions, e.g., a four-tap transformer can provide taps at 0.25, 0.5, 0.75, 1.0 (linear) or 0.0625, 0.125, 0.25, and 0.5 (Vernier). (The limitations of the Vernier—in this case, that the maximum obtainable amplitude is 0.9375—are less ...

  4. Distribution transformer - Wikipedia

    en.wikipedia.org/wiki/Distribution_transformer

    Transformers designed for below-grade installation can be designed for periodic submersion in water. [14] Distribution transformers may include an off-load tap changer, which slightly adjusts the ratio between primary and secondary voltage to bring the customer's voltage within the desired range on long or heavily loaded lines. [citation needed]

  5. Autotransformer - Wikipedia

    en.wikipedia.org/wiki/Autotransformer

    In electrical engineering, an autotransformer is an electrical transformer with only one winding. The "auto" (Greek for "self") prefix refers to the single coil acting alone. In an autotransformer, portions of the same winding act as both the primary winding and secondary winding sides of the transformer. In contrast, an ordinary transformer ...

  6. Voltage regulation - Wikipedia

    en.wikipedia.org/wiki/Voltage_regulation

    a load tap changer (LTC) at the substation transformer, which changes the turns ratio in response to load current and thereby adjusts the voltage supplied at the sending end of the feeder; voltage regulators , which are essentially transformers with tap changers to adjust the voltage along the feeder, so as to compensate for the voltage drop ...

  7. Voltage control and reactive power management - Wikipedia

    en.wikipedia.org/wiki/Voltage_control_and...

    regulating transformers (e.g., tap-changing transformers). The passive compensation devices can be permanently attached, or are switched (connected and disconnected) either manually, using a timer, or automatically based on sensor data. [14] The active devices are by nature self-adjusting. [10]

  8. Here are 12 well-known companies that went bankrupt in 2024 - AOL

    www.aol.com/finance/12-well-known-companies-went...

    Stoli. Stoli Group USA, the owner of the namesake vodka, filed for bankruptcy in December. A number of things went wrong for the unit, including a slowing demand for spirits, a major cyberattack ...

  9. Center tap - Wikipedia

    en.wikipedia.org/wiki/Center_tap

    In switch-mode power supplies, center-tapped transformers are often used, sometimes with single diodes or a dual diode half-bridge [2] to optimize their dynamic electromagnetic behavior at the expense of the extra windings. [3] Phantom power can be supplied to a condenser microphone using center tap transformers. One method, called "direct ...