enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Tap changer - Wikipedia

    en.wikipedia.org/wiki/Tap_changer

    However, a transformer may include a tap changer on each winding if there are advantages to do so. For example, in power distribution networks, a large step-down transformer may have an off-load tap changer on the primary winding and an on load automatic tap changer on the secondary winding or windings. The high voltage tap is set to match long ...

  3. Tap converter - Wikipedia

    en.wikipedia.org/wiki/Tap_converter

    Both linear spacing and power-of-two-style Vernier spacing can be employed in establishing the tap positions, e.g., a four-tap transformer can provide taps at 0.25, 0.5, 0.75, 1.0 (linear) or 0.0625, 0.125, 0.25, and 0.5 (Vernier). (The limitations of the Vernier—in this case, that the maximum obtainable amplitude is 0.9375—are less ...

  4. Autotransformer - Wikipedia

    en.wikipedia.org/wiki/Autotransformer

    In electrical engineering, an autotransformer is an electrical transformer with only one winding. The "auto" (Greek for "self") prefix refers to the single coil acting alone. In an autotransformer, portions of the same winding act as both the primary winding and secondary winding sides of the transformer. In contrast, an ordinary transformer ...

  5. Distribution transformer - Wikipedia

    en.wikipedia.org/wiki/Distribution_transformer

    Transformers designed for below-grade installation can be designed for periodic submersion in water. [14] Distribution transformers may include an off-load tap changer, which slightly adjusts the ratio between primary and secondary voltage to bring the customer's voltage within the desired range on long or heavily loaded lines. [citation needed]

  6. Induction regulator - Wikipedia

    en.wikipedia.org/wiki/Induction_regulator

    Since the 1930s it has been replaced in distribution network applications by the tap transformer. Its usage is now mostly confined to electrical laboratories, electrochemical processes and arc welding. With minor variations, its setup can be used as a phase-shifting power transformer.

  7. Voltage regulation - Wikipedia

    en.wikipedia.org/wiki/Voltage_regulation

    a load tap changer (LTC) at the substation transformer, which changes the turns ratio in response to load current and thereby adjusts the voltage supplied at the sending end of the feeder; voltage regulators , which are essentially transformers with tap changers to adjust the voltage along the feeder, so as to compensate for the voltage drop ...

  8. 7 of the most famous American investors - AOL

    www.aol.com/finance/7-most-famous-american...

    In the latter book, Graham introduces the character of Mr. Market, a metaphor for how the market works and an attempt to show how manic the market can be. One day Mr. Market may be willing to sell ...

  9. Voltage control and reactive power management - Wikipedia

    en.wikipedia.org/wiki/Voltage_control_and...

    regulating transformers (e.g., tap-changing transformers). The passive compensation devices can be permanently attached, or are switched (connected and disconnected) either manually, using a timer, or automatically based on sensor data. [14] The active devices are by nature self-adjusting. [10]