Search results
Results from the WOW.Com Content Network
To apply a Q test for bad data, arrange the data in order of increasing values and calculate Q as defined: Q = gap range {\displaystyle Q={\frac {\text{gap}}{\text{range}}}} Where gap is the absolute difference between the outlier in question and the closest number to it.
In statistical quality control, the CUSUM (or cumulative sum control chart) is a sequential analysis technique developed by E. S. Page of the University of Cambridge. It is typically used for monitoring change detection. [1] CUSUM was announced in Biometrika, in 1954, a few years after the publication of Wald's sequential probability ratio test ...
The new multiple range test proposed by Duncan makes use of special protection levels based upon degrees of freedom.Let , = be the protection level for testing the significance of a difference between two means; that is, the probability that a significant difference between two means will not be found if the population means are equal.
Z-test tests the mean of a distribution. For each significance level in the confidence interval, the Z-test has a single critical value (for example, 1.96 for 5% two tailed) which makes it more convenient than the Student's t-test whose critical values are defined by the sample size (through the corresponding degrees of freedom). Both the Z ...
Critical value or threshold value can refer to: A quantitative threshold in medicine, chemistry and physics; Critical value (statistics), boundary of the acceptance region while testing a statistical hypothesis; Value of a function at a critical point (mathematics) Critical point (thermodynamics) of a statistical system.
The value q s is the sample's test statistic. (The notation | x | means the absolute value of x; the magnitude of x with the sign set to +, regardless of the original sign of x.) This q s test statistic can then be compared to a q value for the chosen significance level α from a table of the studentized range distribution.
For a Gaussian process, the approximation that the number of peaks above the critical value and the number of upcrossings of the critical value are the same is good for y max /σ y > 2 and for narrow band noise. [1] For power spectral densities that decay less steeply than f −3 as f→∞, the integral in the numerator of N 0 does not converge.
Hartley's test is related to Cochran's C test [6] [7] in which the test statistic is the ratio of max(s j 2) to the sum of all the group variances.Other tests related to these, have test statistics in which the within-group variances are replaced by the within-group range.