enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Synchronization (alternating current) - Wikipedia

    en.wikipedia.org/wiki/Synchronization...

    In an alternating current (AC) electric power system, synchronization is the process of matching the frequency, phase and voltage of a generator or other source to an electrical grid in order to transfer power. If two unconnected segments of a grid are to be connected to each other, they cannot safely exchange AC power until they are synchronized.

  3. Short circuit ratio (synchronous generator) - Wikipedia

    en.wikipedia.org/wiki/Short_circuit_ratio...

    high-SCR generator has more synchronizing power, making it easier to operate generators in parallel. Therefore, in practice the design of a generator is seeking an SCR that balances benefits and drawbacks for a particular application. [7] SCR is a measure of the electrical stiffness (also known as a synchronizing coefficient [8]) of the

  4. ANSI device numbers - Wikipedia

    en.wikipedia.org/wiki/ANSI_device_numbers

    Today, microprocessor-based relays can perform many protective functions in one device. [1] When one device performs several protective functions, it is typically denoted "11" by the standard as a "Multifunction Device", but ANSI Device Numbers are still used in documentation like single-line diagrams or schematics to indicate which specific ...

  5. Synchroscope - Wikipedia

    en.wikipedia.org/wiki/Synchroscope

    An example of synchroscope operation on a hydroelectric generator. Synchroscopes are used in any power plant that connects to an outside electrical grid and also in isolated plants containing more than one generator. Each generator must be synchronized with the others before being connected to the plant bus. If line voltages are unequal when ...

  6. Droop speed control - Wikipedia

    en.wikipedia.org/wiki/Droop_speed_control

    Droop speed control is a control mode used for AC electrical power generators, whereby the power output of a generator reduces as the line frequency increases. It is commonly used as the speed control mode of the governor of a prime mover driving a synchronous generator connected to an electrical grid. It works by controlling the rate of power ...

  7. Synchronous impedance curve - Wikipedia

    en.wikipedia.org/wiki/Synchronous_impedance_curve

    A diagram with multiple synchronous machine curves; short-circuit curve is the rightmost The synchronous impedance curve (also short-circuit characteristic, SCC) of a synchronous generator is a plot of the output short circuit current as a function of the excitation current or field.

  8. Relay logic - Wikipedia

    en.wikipedia.org/wiki/Relay_logic

    There are also pocket sized printers that print onto an adhesive backed label that can be wrapped around the wire. The basic format for relay logic diagrams is as follows: 1. The two vertical lines that connect all devices on the relay logic diagram are labeled L1 and L2. The space between L1 and L2 represents the voltage of the control circuit. 2.

  9. Power-system automation - Wikipedia

    en.wikipedia.org/wiki/Power-system_automation

    A protective relay is an IED designed to sense power-system disturbances and automatically perform control actions on the I&C system and the power system to protect personnel and equipment. The relay has local termination so that the copper conductors for each contact do not have to be routed to a central termination panel associated with RTU.