enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Specific fan power - Wikipedia

    en.wikipedia.org/wiki/Specific_fan_power

    SFP for a given fan system and operating point (combination of flow rate and pressure rise) is defined as: = where: is the electrical power used by the fan (or sum of all fans in the ventilation system) [kW]

  3. Affinity laws - Wikipedia

    en.wikipedia.org/wiki/Affinity_laws

    The affinity laws (also known as the "Fan Laws" or "Pump Laws") for pumps/fans are used in hydraulics, hydronics and/or HVAC to express the relationship between variables involved in pump or fan performance (such as head, volumetric flow rate, shaft speed) and power. They apply to pumps, fans, and hydraulic turbines. In these rotary implements ...

  4. Axial fan design - Wikipedia

    en.wikipedia.org/wiki/Axial_fan_design

    The fan is designed to produce a pressure difference, and hence force, to cause a flow through the fan. Factors which determine the performance of the fan include the number and shape of the blades. Fans have many applications including in wind tunnels and cooling towers. Design parameters include power, flow rate, pressure rise and efficiency. [1]

  5. High-volume low-speed fan - Wikipedia

    en.wikipedia.org/wiki/High-volume_low-speed_fan

    A commercial fan delivering air at 20 miles per hour (mph) requires about 64 times as much power as a similar sized fan delivering air at five mph. [8] Airspeed, combined with fan "effectiveness," means that when the objective is to cool people or animals, very large, low-speed commercial fans are more efficient and effective than small high ...

  6. Specific pump power - Wikipedia

    en.wikipedia.org/wiki/Specific_pump_power

    Specific Pump Power (SPP) is a metric in fluid dynamics that quantifies the energy-efficiency of pump systems. It is a measure of the electric power that is needed to operate a pump (or collection of pumps), relative to the volume flow rate. It is not constant for a given pump, but changes with both flow rate and pump pressure.

  7. Orders of magnitude (power) - Wikipedia

    en.wikipedia.org/wiki/Orders_of_magnitude_(power)

    kilo-(kW) 1–3 × 10 3 W tech: heat output of a domestic electric kettle: 1.1 × 10 3 W tech: power of a microwave oven: 1.366 × 10 3 W astro: power per square meter received from the Sun at the Earth's orbit: 1.5 × 10 3 W tech: legal limit of power output of an amateur radio station in the United States up to 2 × 10 3 W

  8. Turn Off the Oven for the Easiest No-Bake Eggnog Pie - AOL

    www.aol.com/turn-off-oven-easiest-no-211700321.html

    Yields: 6-8 servings. Prep Time: 20 mins. Total Time: 12 hours 20 mins. Ingredients. 1 c. cold eggnog. 1/2 tsp. ground nutmeg, plus more for garnish. 1 (3.4-oz.) box instant vanilla pudding mix

  9. Cooling load - Wikipedia

    en.wikipedia.org/wiki/Cooling_load

    The cooling load [3] is calculated to select HVAC equipment that has the appropriate cooling capacity to remove heat from the zone. A zone is typically defined as an area with similar heat gains, similar temperature and humidity control requirements, or an enclosed space within a building with the purpose to monitor and control the zone's temperature and humidity with a single sensor e.g ...