enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Duct leakage testing - Wikipedia

    en.wikipedia.org/wiki/Duct_leakage_testing

    Duct leakage test in the US. A duct leakage tester is a diagnostic tool designed to measure the airtightness of forced air heating, ventilating and air-conditioning (HVAC) ductwork. A duct leakage tester consists of a calibrated fan for measuring an air flow rate and a pressure sensing device to measure the pressure created by the fan flow.

  3. Blower door - Wikipedia

    en.wikipedia.org/wiki/Blower_door

    Duct leakage testing of forced air heating/cooling systems - both supply (vents) ducts and return ducts can be tested to determine if and how much they leak air. A duct test can be combined with a blower door test to measure the total leakage to outside, measuring effective leakage to the outside of the house only.

  4. Ductwork airtightness - Wikipedia

    en.wikipedia.org/wiki/Ductwork_airtightness

    There are two major systems to classify ductwork airtightness, one based on European standards, the other based on ASHRAE standard 90.1-2010.Both are based on the leakage airflow rate at a given ductwork pressure divided by the product of the ductwork surface area and the same ductwork pressure raised to the power 0.65.

  5. Testing, adjusting, balancing - Wikipedia

    en.wikipedia.org/wiki/Testing,_adjusting,_balancing

    In heating, ventilation, and air conditioning (HVAC), testing, adjusting and balancing (TAB) are the three major steps used to achieve proper operation of heating, ventilation, and air conditioning systems. TAB usually refers to commercial building construction and the specialized contractors who employ personnel that perform this service.

  6. Pressurisation ductwork - Wikipedia

    en.wikipedia.org/wiki/Pressurisation_ductwork

    The purpose of pressurisation ductwork is to maintain positive pressure in building spaces to prevent smoke from entering from other spaces in which a fire is occurring. It is typically used in exit stairways, corridors, and lobbies.

  7. Air Movement and Control Association - Wikipedia

    en.wikipedia.org/wiki/Air_Movement_and_Control...

    It applies to a fan or other air moving device when air is used as the test gas with the following exceptions: (a) air circulating fans (ceiling fans, desk fans); (b) positive pressure ventilators; (c) compressors with inter-stage cooling; (d) positive displacement machines; (e) test procedures to be used for design, production, or field testing.

  8. Baby Donkey's Bedtime 'Wiggling' Routine Has Everyone ... - AOL

    www.aol.com/baby-donkeys-bedtime-wiggling...

    The donkey's mama was so impressed by him. The little guy was on his way to learning how to roll over! He just wanted to practice his new moves real quick before it was time to go to sleep.

  9. Process duct work - Wikipedia

    en.wikipedia.org/wiki/Process_Duct_Work

    This suction pressure operates to cause suction pressure collapse on the duct side walls. Also this pressure operates perpendicular to the duct "expansion joints" to create an additional load on the duct supports that adds to dead, and live loads. Please note: duct pressure loads vary with temperature, as the gas density varies with temperature ...